Paradox Hellas S.A. EVO96 Door User Manual


 
User’s Manual 17
7.0 Using Access Control
7.1 Entering & Exiting
Depending on how your system is installed and on the type of keypad, there are various
ways to enter and exit Access Control doors:
Present your Access Control card to the reader or the
DGP2-641RB keypad. The system will verify that the
card is allowed access according to its assigned Access
Level and Schedule. If it is accepted, the system will
unlock the door. The reader’s light can be programmed
by the installer to turn green or extinguish briefly to
indicate that the door can be opened.
When the motion detector detects movement (Request
for Exit), it will unlock the door to permit passage from
inside.
Enter your user access code on the keypad and press
[
ACC].
If the Access Control door is on a “Door Unlocked
Schedule”, you may be able to open Access Control
doors without using a user access code or an Access
Control card. Depending on the door’s programming, the door can remain unlocked
during the entire programmed schedule or the door can unlock once a valid Access
Control card is presented to the reader during the schedule and then will remain
unlocked for the remainder of the schedule.
7.2 Arming and Disarming with Card
7.2.1 Arming with Card
presented to a door during its assigned Schedule (refer to step 8 in section
6.6.1 on page 13).
presented to a door within its assigned Access Level (refer to step 8 in section
6.6.1 on page 13).
programmed to allow arming (options [4] and [5] in section 6.8 on page 15).
assigned to all areas that are assigned to the Access Control door (refer to step
7 in section 6.6.1 on page 13), or assigned to at least one of the areas assigned
to the Access Control door depending on how your installer has programmed
the Access Control door.
7.2.2 Disarming with Card
To disarm and unlock an Access Control door when the area assigned to it is
armed, present your Access Control card to the reader or DGP2-641RB keypad
(door). The Access Control card must be:
presented to a door during its assigned Schedule (refer to step 8 in section
6.6.1 on page 13).
presented to a door within its assigned Access Level (refer to step 8 in section
6.6.1 on page 13).
programmed to allow disarming (option [2] in section 6.8 on page 15).
assigned to all areas that are assigned to the Access Control door (refer to step
7 in section 6.6.1 on page 13), or assigned to at least one of the areas assigned
to the Access Control door depending on how your installer has programmed
the Access Control door.
LCD ICON LED
LCD
DGP2-641RB only
LCD
DGP2-641RB only