Panasonic CU-TE12DKE Air Conditioner User Manual


 
[Intake Air Temp. - Remote Controller Setting Temp.] >
[Thermostat-OFF Temp. +0.5 °C]
Operated in corresponding frequency.
Frequency is decided after a completion of the starting
control (in 60 seconds).
When Room Temp. is below [Thermostat-OFF Temp.]
continuously for 3 minutes or more, it turns to Thermostat-
OFF operation.
Cooling Power TE9DKE TE12DKE
Intake Air Temp.
Difference (°C)
Maximum 2.7kW 4.0kW
Rated 2.5kW 3.6kW
Intermediate ~ ~
Minimum 0.8kW 0.8kW
(-1.00) OFF —- —-
Table (b): Outdoor Air Temperature Shifting
Mode: Outdoor Temperature, X (°C): Temperature Shift (°C)
TE9DKE TE12DKE
Cooling/Soft Dry 38 X 0.00 0.00
30 X 38 0.00 0.00
23 X 30 0.00 0.00
X 23 0.00 0.00
Heating 21 X 0.00 0.00
17 X 21 0.00 0.00
9 X 17 0.00 0.00
5 X 9 +0.50 +1.00
1 X 5 +1.00 +1.25
X 1 +1.50 +2.00
Table (c): Fan Speed Shifting
Mode: Fan Speed: Temperature Shift (°C)
Cooling All +1.25
Soft Dry All +1.0
Heating Lo +1.0
Hi, Me-, Me, Me+, Auto +0.25 (TE9DKE), +0.50
(TE12DKE)
Table (d): Start-Up Shifting
Mode within 60 Minutes from Start-up: Temperature Shift (°C)
Cooling/Soft Dry -1.0
Heating +2.0
9.2. Indoor Power Relay Control
The Power Relay turns on under the following conditions.
1. For three minutes, when plugged in the A/C or the Error Reset button on remote controller is pressed.
2. During Installation Check Mode and following for three minutes after checking.
3. During On-timer sampling and during Preliminary operation.
4. During Operation and following for three minutes after the operation is stopped.
5. During Auto Operation, Test run, Forced Heating or Odour Removal Operation and following for three minutes after the
operation is stopped.
9.3. Room Air Temperature Control (Compressor Control)
Operating frequency of a compressor is decided according to temperature differences between remote controller setting and
room temperatures. A relative method which gives frequency changes, based on the decided frequency, will provide you with
comfortable room environment that is not affected by operating conditions.
9.3.1. Cooling Operation
9.3.1.1. Thermostat Control
21
CS-TE9DKE CU-TE9DKE / CS-TE12DKE CU-TE12DKE