Panasonic CU-E21CKE Air Conditioner User Manual


 
1. Relationship between the condition of the air conditioner and pressure and electric current
Cooling Mode Heating Mode
Condition of the air
conditoner Low Pressure High Pressure Electric current
during operation
Low Pressure High Pressure Electric current
during operation
Insufficient refrigerant
(gas leakage)
Clogged capillary tube
or Strainer
Short circuit in the
indoor unit
Heat radiation
deficiency of the
outdoor unit
Inefficient compression
Carry on the measurements of pressure, electric current, and temperature fifteen minutes after an operation is started.
12.2. Breakdown Self Diagnosis Function
Once abnormality detected during operation, the unit will immediately stop its operation (Timer LED is blinking) and maximum of
three error codes (abnormality) will be saved in memory. The abnormality of the operation can be identified through the below
breakdown diagnosis method:
Press CHECK button at remote control continuously for more than five seconds to turn on the diagnosis mode, H11 will be
displayed at remote control.
By pressing the TMER
button once, next error code will be displayed; press V button once, previous error code will be
displayed.
If error code displayed matches the error code saved in unit memory (abnormality detected), four beep sounds will be heard
and Power LED will light on. Otherwise, one beep sound is heard.
If CHECK button is press again during Cooling operation using test run operation mode for 30 seconds, the diagnosis mode will
turn off.
74