D. Deodorizing Control
i. Control condition
Control at cooling/dry operation and auto fan speed.
No Deodorizing Control is performed during ON timer standby operation and during Anti-freezing control prevention.
ii. Operation
The odor status is arranged as below and it is shifted as follow.
* When COMP is ON 1
→
2
→
3
(Shift to 4 when COMP is OFF)
* When COMP is OFF 4
→
5
→
4
←→
5
(Shift to 1 when COMP is ON)
* Start from 4 if the Thermostat is OFF during the start operation.
Odor Status 1 2 3 4 5 4 5 4.5.4... 1
Status Shift
according to COMP
ON OFF ON
Status Shift
according
Cooling
zone
40 50 — 20 90 20 90 .......
to time (s) Dry zone ON
Fan Speed
Cooling
zone
OFF
SLo
Auto Fan Speed
SLo
OFF
SLo OFF .......
Dry zone OFF SLo OFF
8.1.8. Outdoor Fan Motor Operation
Outdoor fan motor is operated with 15 fan speed. It starts when compressor starts operation and it stops 30 seconds after
compressor stops operation.