Panasonic CS-MKS12NKU Air Conditioner User Manual


 
Outdoor Unit : CU-4KS24NBU
Indoor Unit : CS-KS18NB4UW + CS-MKS12NB4U + CS-MKS12NB4U
Power Supply : 230V Single Phase 60Hz
RATING CAPACITY: 24,800 BTU/h AIR FLOW RATE: 812 CFM
INDOOR OUTDOOR
ENT. TEMP.
o
F (
o
C) AMBIENT TEMP.
o
F (
o
C)
WB DB 15 25 35 45 55
(-9.4) (-3.9) (1.7) (7.2) (12.8)
TC 24,890 24,830 24,880 25,090 25,020
72 (22.2) SHC 19,360 24,830 19,360 19,520 19,520
59 76 (24.4) SHC 22,200 24,830 22,200 22,200 22,200
(15.0) 80 (26.7) SHC 24,890 24,830 24,880 25,090 25,020
84 (28.9) SHC 24,890 24,830 24,880 25,090 25,020
88 (31.1) SHC 24,890 24,830 24,880 25,090 25,020
TC 25,020 25,050 25,250 25,620 25,660
72 (22.2) SHC 15,730 25,050 15,890 16,050 16,050
63 76 (24.4) SHC 18,570 25,050 18,570 18,730 18,890
(17.2) 80 (26.7) SHC 21,410 25,050 21,570 21,730 21,730
84 (28.9) SHC 24,250 25,050 24,250 24,410 24,570
88 (31.1) SHC 25,020 25,050 25,250 25,620 25,660
TC 24,930 25,080 25,450 26,030 26,200
72 (22.2) SHC 12,100 25,080 12,260 12,420 12,580
67 76 (24.4) SHC 14,790 25,080 15,100 15,260 15,420
(19.4) 80 (26.7) SHC 17,780 25,080 17,940 18,260 18,260
84 (28.9) SHC 20,460 25,080 20,780 20,940 21,100
88 (31.1) SHC 23,300 25,080 23,460 23,780 23,780
TC 24,560 24,850 25,440 26,280 26,600
72 (22.2) SHC 8,160 24,850 8,480 8,790 8,950
71 76 (24.4) SHC 11,000 24,850 11,320 11,630 11,630
(21.7) 80 (26.7) SHC 13,840 24,850 14,160 14,470 14,630
84 (28.9) SHC 16,680 24,850 16,990 17,310 17,310
88 (31.1) SHC 19,360 24,850 19,680 19,990 20,150
TC 23,930 24,370 25,200 26,320 26,810
75 76 (24.4) SHC 7,220 24,370 7,690 8,000 8,160
(23.9) 80 (26.7) SHC 10,050 24,370 10,530 10,840 11,000
84 (28.9) SHC 12,890 24,370 13,370 13,680 13,840
88 (31.1) SHC 15,730 24,370 16,050 16,520 16,680
NOTE
< Cooling Capacity (Low Ambient) >
TC : Total Cooling Capacity (BTU/h) SHC : Sensible Heat Capacity (BTU/h)
1.
2. Above data represents the value when the operation frequency of a compressor is fixed.
Above data does not take Freeze Prevention Protection during cooling operation into account.
For this reason, the value may vary from the actual cooling characteristics.