Panasonic CS-MKS12NKU Air Conditioner User Manual


 
Outdoor Unit : CU-3KS19NBU
Indoor Unit : CS-MKS9NKU × 3
Power Supply : 230V Single Phase 60Hz
< Cooling Capacity (Low Ambient) >
5-3. Cooling Capacity (Low Ambient)
TC : Total Cooling Capacity (BTU/h) SHC : Sensible Heat Capacity (BTU/h)
NOTE
RATING CAPACITY: 18,800 BTU/h AIR FLOW RATE: 777 CFM
INDOOR OUTDOOR
ENT. TEMP.
o
F (
o
C) AMBIENT TEMP.
o
F (
o
C)
WB DB 15 25 35 45 55
(-9.4) (-3.9) (1.7) (7.2) (12.8)
TC 19,220 19,090 19,080 19,160 19,010
72 (22.2) SHC 16,390 19,090 16,240 16,390 16,240
59 76 (24.4) SHC 18,950 19,090 18,950 18,950 18,950
(15.0) 80 (26.7) SHC 19,220 19,090 19,080 19,160 19,010
84 (28.9) SHC 19,220 19,090 19,080 19,160 19,010
88 (31.1) SHC 19,220 19,090 19,080 19,160 19,010
TC 19,620 19,540 19,610 19,780 19,680
72 (22.2) SHC 13,220 19,540 13,070 13,220 13,220
63 76 (24.4) SHC 15,780 19,540 15,780 15,940 15,780
(17.2) 80 (26.7) SHC 18,650 19,540 18,650 18,650 18,650
84 (28.9) SHC 19,620 19,540 19,610 19,780 19,680
88 (31.1) SHC 19,620 19,540 19,610 19,780 19,680
TC 19,910 19,890 20,060 20,340 20,320
72 (22.2) SHC 9,900 19,890 9,900 10,050 10,050
67 76 (24.4) SHC 12,620 19,890 12,620 12,770 12,770
(19.4) 80 (26.7) SHC 15,330 19,890 15,480 15,480 15,480
84 (28.9) SHC 18,050 19,890 18,050 18,200 18,200
88 (31.1) SHC 19,910 19,890 20,060 20,340 20,320
TC 20,060 20,120 20,400 20,830 20,890
72 (22.2) SHC 6,430 20,120 6,580 6,730 6,730
71 76 (24.4) SHC 9,150 20,120 9,300 9,450 9,450
(21.7) 80 (26.7) SHC 12,010 20,120 12,160 12,310 12,310
84 (28.9) SHC 14,580 20,120 14,730 14,880 14,880
88 (31.1) SHC 17,290 20,120 17,440 17,600 17,600
TC 20,040 20,180 20,600 21,180 21,340
75 76 (24.4) SHC 5,980 20,180 6,130 6,280 6,280
(23.9) 80 (26.7) SHC 8,690 20,180 8,840 9,000 9,150
84 (28.9) SHC 11,410 20,180 11,560 11,710 11,710
88 (31.1) SHC 14,130 20,180 14,280 14,430 14,430
1.
2. Above data represents the value when the operation frequency of a compressor is fixed.
Above data does not take Freeze Prevention Protection during cooling operation into account.
For this reason, the value may vary from the actual cooling characteristics.
56