Omnitron Systems Technology A10 Stove User Manual


 
9
Combustible Wall Clearance for Rear Vent Installation
If the stove is to be placed at side and back walls of combustible materials the following clearances
must be kept:
Refer to the manufacturer’s instructions concerning installation of listed single wall connector pipe,
wall thimble and chimney
Alcove Installation Requirements:
Whenever the stove is placed in a location where the ceiling height is less than 7’ tall, it is
considered an alcove installation. Because of the reduced height, the special requirements listed
below must be met.
Alcove installation Connector pipe A B C D E F
USA Double wall 60” 51” 22” 12” 10” 12.5”
Canada Double wall 1520 1284 558 304 254 317
Rear outlet through wall Connector pipe A B D
USA Single wall 11" 6" 21"
Canada Single wall 280 152 533