Rear Vent Installation
For venting into a masonry or a back standing steel chimney through the top vent the top horizontal
portion of a single wall connector pipe can be located not closer than 18” below a combustible
ceiling.
From the factory the stove is prepared for top mounting of the flue collar, but all SCAN stoves have
an optional flue outlet, therefore the flue collar can be fitted either on the top or at the rear as
required.
Mounting the flue collar for rear outlet:
1. Remove the part of the back plate inside the groove for access to the rear outlet.
2. Remove the part of the inner back plate inside the groove for access to the rear outlet.
3. Remove the inner cover plate (cooking ring) by means of the hexagon spanner.
4. The flue collar is fitted from the outside into the discharge hole of the firebox in such a way
that the bracket is located on the inside.
5. Place the cooking ring on top so that this is level with the top plate.
Rear venting into a masonry or steel chimney through a thimble or other vent configuration than
descript here must follow local codes or NFPA 211 or CAN/CSA-B365 guidelines and methods.
Required installation components:
Chimney cap
Insulated chimney
Tee section
Tee support bracket
Chimney connector pipe
Wall thimble
Wall strap