Napoleon Fireplaces GVFS20P Water Heater User Manual


 
6
W415-0559 / 02.15.06
MAINTAIN THESE MINIMUM CLEARANCES
TO COMBUSTIBLES:
A. 4" B. 2"* C. 2"
Provide adequate ventilation and combustion air.
Provide adequate accessibility clearance for servicing
and operating the stove.
Never obstruct the front opening of the stove.
As long as clearance to combustibles is kept within the re-
quired distances, the most desirable and benefi cial location
for a Napoleon stove is in the centre of a building, thereby
allowing the most effi cient use of the heat created. The loca-
tion of windows, doors and the traffi c fl ow in the room where
the stove is to be located should be considered.
FIGURE 2
LOCATION & CLEARANCES
GVFS20
PILOT INDICATOR
LIGHT BATTERY
REPLACEMENT
If the pilot indicator light no longer fl ashes and the pilot is
burning, the batteries may require replacing.
Four "AA" batteries are required and should be replaced
annually.
1. Open the switch housing by removing the top screw, then
pivoting the box open.
2. Remove the 4 "AA" batteries and replace using the new
ones.
3. Pivot the box closed and re-secure using the screw re-
moved in step 1.
+
+
+
+
-
-
-
-
19
1
/
4
"
9
5
/
8
"
25
3
/
8
"
15
3
/
4
"
STOVE SHOULD NOT BE INSTALLED DIRECTLY ON CARPETING.
MINIMUM 48". FROM TOP TO CEILING
*IF LESS THAN 5" CLEARANCE IS MAINTAINED BETWEEN THE
BACK OF THE STOVE AND THE BACK WALL, IT WILL BE NECESSARY
TO DISCONNECT THE GAS PIPE TO MOVE THE STOVE OUT FOR
INSTALLATION OR SERVICE OF THE BLOWER.
CARBON MONOXIDE POISONING MAY LEAD TO DEATH
Early signs of carbon monoxide poisoning
resemble the fl u, with headache, dizziness and/
or nausea. If you have these signs, the heater
may not be working properly.
Get fresh air at once! Have heater serviced.
Some people---pregnant women, persons with
heart or lung disease, anemia, those under the infl u-
ence of alcohol, those at high altitudes--- are more
affected by carbon monoxide than others.
THIS GAS STOVE SHOULD BE INSTALLED AND SERVICED BY A QUALIFIED INSTALLER to conform with local codes.
Installation practices vary from region to region and it is important to know the specifi cs that apply to your area,