Napoleon Fireplaces GVFS20P Water Heater User Manual


 
14
W415-0559 / 02.15.06
Main burner goes
out; pilot stays on.
Pilot fl ame is not large enough
or not engulfi ng the thermo-
pile
- service or replace Oxygen Depletion Sensor System
- correct piping and/or regulator to provide correct pressure
Thermopile shorting
- clean thermopile connection to the valve. Reconnect.
- replace Oxygen Depletion Sensor System / valve.
Remote wall switch wire is too
long; too much resistance in
the system.
- shorten wire to correct length or wire gauge.
Faulty thermostat or switch.
- replace.
Pilot burning; no
gas to main burner;
gas knob is on ‘HI’;
wall switch / ther-
mostat is on.
Themostat or switch is de-
fective.
- connect a jumper wire across the wall switch terminals; if main burner
lights, replace switch / thermostat.
Main burner orifice is - remove stoppage in orifi ce.
Faulty valve.
- replace.
Wall switch wiring is defec-
tive.
- disconnect wires from valve. Connect a jumper wire across terminals
1 & 3; if the main burner lights, check the wires for defects and / or
replace wires.
Pilot goes out when
the gas knob is re-
leased.
The gas valve has
an interlock device
which will not al-
low the pilot burn-
er to be lit until
the thermocouple
has cooled. Allow
approximately 60
seconds for the
thermocouple to
cool.
System is not correctly
purged.
- purge the gas line.
Thermocouple shorting /
faulty.
- loosen and tighten thermocouple.
- clean thermocouple and valve connection.
- replace Oxygen Depletion Sensor System
- test and replace valve.
Faulty valve.
- replace.
Out of propane gas. - fi ll the tank.
Pilot fl ame is not large enough.
(Supply pressure too low.)
- service or replace Oxygen Depletion Sensor System
ELECTRODE
PILOT
BURNER
THERMOCOUPLE
THERMOPILE
Pilot will not light.
- check if pilot can be lit by a match
- check that the wire is connected to the push button ignitor.
- check if the push button ignitor needs tightening.
- replace the wire if the wire insulation is broken or frayed.
- replace the electrode if the ceramic insulator is cracked or broken.
- replace the push button ignitor.
No spark at pilot burner
- fi ll the tank.Out of propane gas
No gas at the pilot burner
- check that the manual valve is turned on.
- check the pilot orifi ce for blockage.
- replace the valve / Oxygen Depletion Sensor System.
- call the gas distributor.
Main burner goes
out; pilot goes out.
Insuffi cient air supply
- open window or door. (Use one of the methods described in ANSI
Z223.1 Section 5.3 or the applicable local code.)
Out of propane gas. - fi ll the tank.
Pilot fl ame is not large enough.
(Supply pressure too low.)
- service or replace Oxygen Depletion Sensor System
- correct piping and / or regulator to provide correct pressure.
TROUBLE SHOOTING GUIDE