19
W415-0098 / C / 04.19.06
RELIEF DOOR GASKET
RELIEF DOOR
TWIN BLOWER
P
I
P
I
L
O
T
N
O
L
O
T
H
I
L
O
F
F
O
BLOW
ER
THERMODISC
black
ground
VARIABLE
SPEED
SWITCH
white
1. Turn off the electrical power and the gas supply to the
stove.
2. Open the lower louvre control door, the two side doors,
and the fire viewing door. Remove the logs.
3. Remove the relief door assembly held on with 6 screws.
Discard the gasket.
4. Disconnect the two blower wires. Remove the blower
bracket held on with 4 screws.
5. Replace the blower using the existing bracket. When
connecting the replacement blower, tighten the screws with-
out distorting the rubber grommets. Replace the bracket/
blower assembly in the unit.
6. Reconnect the two wires. Hold the replacement gasket
in place and reattach the relief door assembly. Replace the
logs. Close all doors.
7. Turn the gas supply and electricity back on.
Because the blower is thermally activated, when turned
on, it will automatically start approximately 15-30 min-
utes after lighting the stove and will run for approximately
30-45 minutes after the stove has been turned off. Use
of the fan increases the output of heat.
Drywall dust will penetrate into the blower bearings caus-
ing irreparable damage and must be prevented from
coming into contact with the blower or its compartment.
Any damage resulting from this condition is not covered
by the warranty policy.
REPLACEMENT BLOWER INSTALLATION
FIGURE 35
FIGURE 34