W415-0098 / C / 04.19.06
In Canada, mobile home installation may be vented hori-
zontally or vertically. In the United States, it may only be
installed vertically. See "Vertical Venting" or "Horizontal Air
Terminal Installation" for installation.
The fireplace is equipped with two 5/16" diameter holes
located near each corner of the base. For mobile home
installations, the fireplace must be fastened in place. Use
#10 screws, inserted through the holes in the base to se-
cure. It is recommended that the fireplace be secured in all
installations.
1. Attach the ad-
justable pipe to
the last section of
rigid piping. Se-
cure with screws
and seal.
2. Install the 4"
aluminum flexible
liner to the stove.
Secure with 3
screws and flat
washers. Seal the
joint and screw
holes using Mill
Pac high tem-
perature sealant
not supplied.
3. Run a bead of
red RTV high tem-
perature sealant
around the inside
of the air intake
collar. Pull the adjustable pipe a minimum 2" into the air
intake collar.
Ensure that the sealant is not visible on the exte-
rior pipes once installation is completed. An op-
tional decorative brass band is available for this
use. (Standard with a GD175 kit). In the event that
the venting must be disassembled, care must be
taken to reseal the venting.
Continue with "Gas Installation" Page 14
STOVE VENT CONNECTION
MOBILE HOME INSTALLATION
2" OVERLAP
SPEED SWITCH
1
4
-
5
/
3
2
"
SCREWS
SELF DRILLING
#8x1/2"
5
-
3
/
4
"
VARIABLE
ON/OFF
SWITCH
SEALANT
HI-TEMP
FIGURE 21