Napoleon Fireplaces GDS 50-N Stove User Manual


 
10
W415-0098 / C / 04.19.06
STORM
COLLAR
FLASHING
CAULKING
WEATHER
SEALANT
2”
AIR INLET
BASE
FIGURE 20
ROOF SUPPORT
FIGURE 18
1. Fasten the roof support to the
roof using the screws provided.
The roof support is optional.
In this case the venting is
to be adequately
supported using
either an alternate
method suitable to
the authority having
jurisdiction or the
optional roof
support.
2. Stretch the inner aluminum flex
liner to the required length. Slip the
liner a minimum of 2” over the inner
sleeve of the air terminal connector
and secure with 3 #8 screws. Seal
using a heavy bead of the high
temperature sealant.
3. Repeat using the outer aluminum
flex liner.
4. Thread the air terminal connector
/ liner assembly down through the
roof. The air terminal must be located
vertically and plumb. Attach the air
terminal connector to the roof support,
ensuring that the top of the air terminal
is 16” above the highest point that it
penetrates the roof.
5. Remove nails from the
shingles, above and to the sides
of the chimney. Place the flashing
over the air terminal connector
leaving a min. 3/4” of the air
terminal connector showing
above the top of the flashing.
Slide the flashing
underneath the sides and
upper edge of the shingles.
Ensure that the air terminal
connector is properly centred
within the flashing, giving a
3/4” margin all around.
Fasten to the roof. Do not
nail through the lower
portion of the flashing. Make
weather-tight by sealing
with caulking. Where
possible, cover the sides
and top edges of the
flashing with roofing
material.
6. Aligning the seams of the terminal and air terminal
connector, place the terminal over the air terminal connector
making sure the liner goes into the hole in the terminal.
Secure with the three screws provided.
7. Apply a heavy bead of weatherproof caulking 2 inches
above the flashing. Note: Maintain a minimum 2” space
between the air inlet base and the storm collar. Install the
storm collar around the air terminal and slide down to the
caulking. Tighten to ensure that a weather-tight seal
between the air terminal and the collar is achieved.
FIGURE 16
FIGURE 17
HORIZONTAL VENTING INSTALLATION
VERTICAL VENTING INSTALLATION
DO NOT CLAMP
THE FLEXIBLE
ALUMINIUM
LINER.
Spacers are attached to
the inner flex liner at
predetermined intervals to
maintain a 1-1/4” air gap to
the outer flex liner. These
spacers must not be
removed.
FOR SAFE AND PROPER OPERAFOR SAFE AND PROPER OPERA
FOR SAFE AND PROPER OPERAFOR SAFE AND PROPER OPERA
FOR SAFE AND PROPER OPERA
TION OF THETION OF THE
TION OF THETION OF THE
TION OF THE
STST
STST
ST
OO
OO
O
VE, FOLLVE, FOLL
VE, FOLLVE, FOLL
VE, FOLL
OO
OO
O
W THE VENTING INSTRW THE VENTING INSTR
W THE VENTING INSTRW THE VENTING INSTR
W THE VENTING INSTR
UC-UC-
UC-UC-
UC-
TIONS EXATIONS EXA
TIONS EXATIONS EXA
TIONS EXA
CTLCTL
CTLCTL
CTL
YY
YY
Y
..
..
.
ALL HORIZONTALL HORIZONT
ALL HORIZONTALL HORIZONT
ALL HORIZONT
AL RAL R
AL RAL R
AL R
UNS MUST HAUNS MUST HA
UNS MUST HAUNS MUST HA
UNS MUST HA
VE A MINI-VE A MINI-
VE A MINI-VE A MINI-
VE A MINI-
MUM MUM
MUM MUM
MUM
¼ INCH¼ INCH
¼ INCH¼ INCH
¼ INCH
RISE PER FOO RISE PER FOO
RISE PER FOO RISE PER FOO
RISE PER FOO
TT
TT
T
.
.
..
.
1. Stretch the 4" diameter alu-
minum flexible liner to the re-
quired length taking into account
the additional length needed for the
finished wall surface.
Spacers are attached to the 4" inner flex liner at predeter-
mined intervals to maintain a 1-1/4" air gap to the 7" outer
stove pipe. These spacers must not be removed.
Slip a 4" diameter length of aluminum flexible liner a mini-
mum of 2" over the inner sleeve of the air terminal. Secure
to the sleeve using 3 screws. Seal the joint and screw
heads using red RTV or Mill Pac high temperature sealant
(not supplied).
2. Slip the first section of 7" diameter stove pipe a mini-
mum of 2" over the outer sleeve of the air terminal. Secure
to the sleeve using 3 screws. Seal the joint and screw
heads using red RTV high temperature sealant.
3. Insert the liners through the firestop / vent pipe shield.
Holding the air terminal (lettering in an upright, readable
position), secure to the exterior wall. Make weather tight by
sealing with caulking (not supplied). The air terminal mount-
ing plate may be recessed (up to
3
/
4
" maximum) into the
exterior wall or siding.
4. If more than one length of liner needs to be used to
reach the stove, couple them together as illustrated in
FIGURE 18. Seal the joints using the same procedure as
described above.
The vent system must be supported approximately every
10 feet along a horizontal run. Use supports or equivalent
non-combustible strapping to maintain the 1" clearance
from combustibles.
INNER FLEX
LINER
OUTER
FLEX
LINER
INNER
SLEEVE
HIGH
TEMPERATURE
SEALANT
AIR
TERMINAL
CONNECTOR
FIGURE 19