14
W415-0098 / C / 04.19.06
Read the section on opening the door in "Finish-
ing" prior to proceeding to prevent damaging the
unit.
Bring the gas line to the stove through either the opening in
the pedestal back or through the floor directly beneath the
pedestal base.
Install rigid black pipe or ½" type L copper tubing with a
shut-off valve to the stove.
Seal and tighten the gas line securely to the flex connector
supplied.
Do not kink the flexible connector.
Mark the two appropriate boxes on the rating plate la-
bel. One to indicate the model type depending on the in-
stallation (direct vent or B-vent). Mark the second box to
indicate the altitude type and the type of fuel being used
(natural gas or propane).
Attach one lead from the spill switch (white wire) to terminal
#3 located on the gas valve and the other (black) on/off
switch lead to valve terminal #1.
Attach the B-Vent label, shown below, in the control area of
the appliance.
Check for gas leaks by brushing on a soap and water solu-
tion. DO NOT USE OPEN FLAME.
Disconnect the existing wires from terminals 1 and 3 (from
the on/off switch) and replace with the leads from the wall
switch/millivolt thermostat.
Disconnect the existing on/off switch wire from terminal 1
on the valve and the black switch wire from the terminal
block. Replace each connection using the wires from the
wall switch/millivolt thermostat. FIGURE 30.
FIGURE 29
FIGURE 31
DIRECT VENT MODELS GDS50 CDVS500 APPROVED FOR
BEDROOM, BATHROOM & BEDSITTING ROOM INSTALLATION.
SUITABLE FOR MOBILE HOME INSTALLATION IF INSTALLED IN
ACCORDANCE WITH THE CURRENT STANDARD
CAN/CSA Z240MH SERIES GAS EQUIPPED MOBILE HOMES, IN
CANADA OR IN THE UNITED STATES THE MANUFACTURED
HOME CONTRUCTION AND SAFETY STANDARD, TITLE 24
CFR, PART 3280. WHEN THIS US STANDARD IS NOT APPLI-
CABLE USE THE STANDARD FOR FIRE SAFETY CRITERIA FOR
MANUFACTURED HOME INSTALLATIONS, SITES AND COM-
MUNITIES, ANSI / NFPA 501A.
HOMOLOGUE POUR INSTALLATION DANS UNE CHAMBRE A
COUCHER, UNE SALLE DE BAIN ET UN STUDIO. APPROPRIE
POUR INSTALLATION DANS UNE MAISON MOBILE SI SON IN-
STALLATION CONFORME AUX EXIGENCES DE LA NORME
CAN/CSA Z240MH SERIE DE MAISONS MOBILES EQUIPEES AU
GAZ, EN VIGUEUR AU CANADA OU AUX ETATS-UNIS DE LA
NORME DE SECURITE ET DE CONSTRUCTION DE MAISONS
MANUFACTUREES, TITRE 24 CFR, SECTION 3280. DANS LE
CAS OU CETTE NORME D'ETATS-UNIS NE PEUT ETRE
APPLIQUEE, SE REFERER A LA NORME RELATIVE AU CRITERE
DE MESURES DE SECURITE CONTRE L'INCENDIE POUR LES
INSTALLATIONS DANS LES MAISONS MANUFACTURES, LES
SITES ET LES COMMUNAUTES, ANSI/NFPA 501A
.
STEADY STATE EFFICIENCY (NG): 75% FAN OFF / 78% FAN ON
STEADY STATE EFFICIENCY (LP): 76% FAN OFF / 79% FAN ON
EFFICACITE CONSTANTE (GN): 75% VENT. ARRETE
78% VENT. FONCTIONNE
EFFICACITE CONSTANTE (GP): 76% VENTILATEUR ARRETE
79% VENTILATEUR FONCTIONNE
STEADY STATE EFFICIENCY APPLIES TO CANADA ONLY /
L'EFFICACITE CONSTANTE S'APPLIQUENT SEULEMENT AU
CANADA.
AFUE (NG/LP) (GN/GP): 65% / 67%
MINIMUM AND MAXIMUM HORIZONTAL VENT LENGTHS ARE
25 INCHES AND 20 FEET RESPECTIVELY. LES LONGUEURS
HORIZONTALES MINIMALE ET MAXIMALE SONT 25 POUCES
ET 20 PIEDS RESPECTIVEMENT.
THE APPLIANCE MUST BE VENTED USING THE APPROPRI-
ATE NAPOLEON VENT KITS. SEE OWNERS INSTALLATION
MANUAL FOR VENTING SPECIFICS. PROPER REINSTALLA-
TION AND RESEALING IS NECESSARY AFTER SERVICING THE
VENT-AIR INTAKE SYSTEM.
L'APPAREIL DOIT EVACUER SES GAZ EN UTILISANT
L'ENSEMBLE D'EVACUATION PROPRE A NAPOLEON.
REFERER AU MANUEL D'INSTALLATION DE PROPRIETAIRE
POUR L'EVACUATION PRECISE. IL EST IMPORTANT DE BIEN
REINSTALLER ET RESCELLER L'EVENT APRES AVOIR AS-
SURE LE MAINTIEN DU SYSTEME DE PRISE D'AIR.
WOLF STEEL LTD
BARRIE, ONTARIO CANADA
MADE IN CANADA / FABRIQUE AU CANADA
WS-385-181
* ALTITUDE DOWNRATING CONDITIONS APPLY TO CANADA
ONLY
LES CONDITIONS DE BAISSE D’EVALUATION SELON
L’ALTITUDE S’APPLIQUENT AU CANADA SEULEMENT
MANIFOLD PRESSURE: 3.5 INCHES W.C. (NG) / 10 INCHES W.C.(LP)
PRESSION AU COLLECTEUR: 3.5" D'UNE COLONNE D'EAU(GN)
10" D'UNE COLONNE D'EAU (PG)
MIN SUPPLY PRESSURE: 4.5" W.C.(NG) / 11" W.C. (LP)
PRESSION D'ALIMENTATION MIN: 4.5" D'UNE COLONNE D'EAU
11" D'UNE COLONNE D'EAU (PG)
MAX. SUPPLY PRESSURE: 7" W.C. (NG) / 13" W.C. (LP)
PRESSION D'ALIMENTATION MAX: 7" D'UNE COLONNE D'EAU
13" D'UNE COLONNE D'EAU (PG)
FOR USE WITH GLASS DOORS CERTIFIED WITH THIS UNIT
ONLY.
UTILISER AVEC LES PORTES VITREES HOMOLOGUEES
SEULEMENT AVEC CETTE UNITE.
WARNING: DO NOT ADD ANY MATERIAL TO THE APPLIANCE,
WHICH WILL COME IN CONTACT WITH THE FLAMES, OTHER
THAN THAT SUPPLIED BY THE MANUFACTURER WITH THE AP-
PLIANCE.
AVERTISSEMENT: N'AJOUTEZ PAS A CET APPAREIL
AUCUN MATERIAU DEVANT ENTRER EN CONTACT
AVEC LES FLAMMES AUTRE QUE CELUI QUI EST FOURNI
AVEC CET APPAREIL PAR LE FABRICANT.
MINIMUM CLEARANCE TO COMBUSTIBLE MATERIAL /
DEGAGEMENTS MINIMAUX DES MATERIAUX COMBUSTIBLES:
A 7" D 17½"
B 2" E 6¼"
C 1" F 9½"
20" TO CEILING FROM STOVE TOP
20" ENTRE LE DESSUS DU FOYER ET LE PLAFOND
ELECTRICAL RATING / CLASS.: 115V 1.5AMP 60HZ
B-VENT MODELS GS50/CS500 APPROVED FOR BED-
ROOM, & BEDSITTING ROOM INSTALLATION. HOMOLOGUE
POUR INSTALLATION DANS UNE CHAMBRE A
COUCHER, & UN STUDIO.
STEADY STATE EFFICIENCY (NG): 71% FAN OFF / 77% FAN
ON
STEADY STATE EFFICIENCY (LP): 73% FAN OFF / 78% FAN
ON
EFFICACITE CONSTANTE (GN): 71% VENT. ARRETE
77% VENT. FONCTIONNE
EFFICACITE CONSTANTE (GP): 73% VENTILATEUR ARRETE
78% VENTILATEUR FONCTIONNE
STEADY STATE EFFICIENCY APPLIES TO CANADA ONLY /
L'EFFICACITE CONSTANTE S'APPLIQUENT SEULEMENT AU
CANADA.
AFUE (NG/LP) (GN/GP): 64% / 67%
THIS APPLIANCE MUST BE INSTALLED USING AN ADAPTER
KIT GS-150KT. CET APPAREIL DOIT ETRE INSTALLE EN UTILI-
SANT UN ENSEMBLE ADAPTATEUR GS-150KT.
NOT FOR USE WITH SOLID FUEL
UN COMBUSTIBLE SOLIDE NE DOIT PAS ETRE UTILISE
AVEC CET APPAREIL
SERIAL NUMBER
NO. DE SERIE
GDS50
0-2000ft (0-610m)
44,000 BTU/h
20,000 BTU/h
33,000 BTU/h
31,200 BTU/h
#34
#43
2000-4500ft (610-1370m)
40,000 BTU/h
18,000 BTU/h
30,000 BTU/h
28,400 BTU/h
#36
#45
2000-4500ft (610-1370m)
36,000 BTU/h
18,000 BTU/h
27,400 BTU/h
26,400 BTU/h
#53
#59
40,000 BTU/h
21,000 BTU/h
30,400 BTU/h
30,000 BTU/h
#53
#57
CERTIFIED UNDER CSA 2.33A-M98, ANSI Z21.88 A-1998
VENTED GAS FIREPLACE HEATER APPLIANCE MUST BE
INSTALLED USING BURNER KIT : GDS50BN-KT,
OR GDS50BP-KT.
HOMOLOGUE SELON LES NORMES FOYER DE CHAUFFAGE
AU GAZ AVEC EVACUATION CET APPAREIL DOIT ETRE
INSTALLE EN UTILISANT UN ENSEMBLE DU BRULEUR:
GDS50BN-KT, OU GDS50BP-KT.
GDS50 -N
GS50-N
CDVS500 -N
CS500-N
GDS50 -P
GS50-P
CDVS500 -P
CS500-P
ALTITUDE / ELEVATION
INPUT / ALIMENTATION
REDUCED INPUT / ALIMENTATION REDUITE
OUTPUT (MODEL GDS50) RENDEMENT
OUTPUT (MODEL GS50) RENDEMENT
FRONT ORIFICE / INJECTEUR AVANT
TURBO ORIFICE / INJECTEUR TURBO
FIGURE 30
ATTACH THIS LABEL IN THE CONTROL AREA OF THE FIREPLACE.
THIS FIREPLACE HAS BEEN CONVERTED TO A ‘B’VENT MODEL.
ATTACHEZ CET ETIQUETTE DANS LA REGION DE CONTROLE DU FOYER.
CE FOYER A ETE CONVERTI A UN MODELE A SYSTEME D’EVACUATION ‘B’.
ws-385-160
GAS INSTALLATION
GAS INSTALLATION B-VENT MODEL GS50 ONLY
DIRECT VENT MODEL GDS50
B-VENT MODEL GS50