Napoleon Fireplaces GD36PTR Indoor Fireplace User Manual


 
27
W415-0210 / E / 06.25.03
After extended periods of non-operation such as fol-
lowing a vacation or a warm weather season, the fire-
place may emit a slight odour for a few hours. This is
caused by dust particles in the heat exchanger burning
off. In both cases, open a window to sufficiently venti-
late the room.
Purge all gas lines with the glass door of the fireplace
removed. Assure that a continuous gas flow is at the
burner before installing the door.
When lit for the first time, the fireplace will emit a slight
odour for a few hours. This is a normal temporary condi-
tion caused by the curing of the logs and the "burn-in"
of internal paints and lubricants used in the manufac-
turing process and will not occur again.
Turn off all gas to the fireplace.
Open windows.
Do not try to light any appliance.
Do not touch any electric switch; do not use any phone
in your building.
Immediately call your gas supplier from a neighbour's
phone. Follow the gas supplier's instructions.
If you cannot reach your gas supplier, call the fire de-
partment.
FLAME
ADJUSTMENT
KNOB
O
T
P
I
L
L
O
I
H
T
P
I
L
O
N
O
F
F
O
PILOT
ON/OFF
KNOB
GAS KNOB
A. This fireplace is equipped with a pilot which must be lit
by hand while following these instructions exactly.
B. Before operating smell all around the fireplace area
for gas and next to the floor because some gas is
heavier than air and will settle on the floor.
C. Use only your hand to turn the gas control knob. Never
use tools. If the knob will not turn by hand, do not try to
repair it. Call a qualified service technician. Force or
attempted repair may result in a fire or explosion.
D. Do not use this fireplace if any part has been under
water. Immediately call a qualified service technician to
inspect the fireplace and replace any part of the control
system and any gas control which has been under wa-
ter.
WARNING: The gas valve has an interlock device which
will not allow the pilot burner to be lit until the thermocou-
ple has cooled. Allow approximately 60 seconds for the
thermocouple to cool.
When lighting and re-lighting, the gas knob cannot be
turned from pilot to off unless the knob is depressed
slightly.
1. Stop! Read the above safety information on this label.
2. Turn off all electric power to the fireplace.
3. Turn the gas knob clockwise to off.
4. Wait five (5) minutes to clear out any gas. If you smell
gas including near the floor. Stop! Follow "B" in the above
safety information on this label. If you don't smell gas go
the next step.
5. Turn gas knob counter-clockwise to pilot.
6. Depress slightly and hold gas knob while lighting the
pilot with the push button ignitor. Keep knob depressed
for one minute, then release. If pilot does not continue to
burn, repeat steps 3 through 5.
7. With pilot lit, depress and turn gas knob counter-clock-
wise to on.
8. If equipped with remote on-off switch/thermostat, main
burner may not come on when you turn valve to on. Remote
switch must be in the on position to ignite burner.
9. Turn on all electric power to
the fireplace.
1. Turn off all electric power to the fireplace if service is to
be performed.
2. Push in gas control knob slightly and turn clockwise to
off. Do not force.
OPERATION / MAINTENANCE
P
I
N
O
L
O
T
F
F
O
FOR YOUR SAFETY READ BEFORE LIGHTING: WHAT TO DO IF YOU SMELL GAS:
LIGHTING INSTRUCTIONS
TO TURN OFF GAS
TURN THE CONTROL VALVE TO THE OFF POSITION WHEN HEATER IS NOT IN USE.