23
W415-0210 / E / 06.25.03
A
C
B
DOOR OPENING AND
CLOSING: The upper lou-
vres must be removed to
allow the door to be opened
or closed. To access the
lower door latch, open the
valve control door. Release
the top and bottom door
latches, located at the right
side of the door.
TO INSTALL THE UPPER
LOUVRES: Insert the up-
per louvres into the slots
on both brackets. Press
the top flange of the hood
into the four clips located
along the top of the unit as
shown.
TO INSTALL THE LOWER
LOUVRE ASSEMBLY: At-
tach each hinge to the fire-
box with 2 screws.
Position the hinge screen into place and with the control
door open, secure to the firebox using three screws.
Optional plated door trim, and arched door facia are avail-
able at your local Napoleon dealer.
LOWER LOUVRES
(VALVE CONTROL DOOR)
c
DOOR LATCH
HOOD
UPPER LOUVRE
a
FLANGE
CLIP
FINISHING
LOUVRE
HOOD
SLOT
BRACKET
b
HINGE SCREEN
d
GVFL LOUVRE INSTALLATION
L36 LOUVRE INSTALLATIONDOOR REMOVAL & INSTALLATION
FIGURE 45 a-c
HOOD
Attach the hood by pressing the
top flange into the clips along
the top of the louvre opening.
Secure using a screw through
the centre slot.
LOWER LOUVRES
Insert the hinge clips into the
slots located at the bottom left
and right corners of the unit.
To remove the louvres, pull the
back tabs of the clips forward,
while pushing the louvre assem-
bly back. Lift the clip.
UPPER LOUVRES
Insert the louvre tabs into the
slots located at the top left and
right corners of the unit.
A
CLIPS
CENTRE
SLOT
FLANGE
SLOT
TAB
B
C
HINGE
CLIP
SLOT
FIGURE 44a-d