Napoleon Fireplaces EF34H Indoor Fireplace User Manual


 
5
W415-0405 / B / 03.25.04
This fireplace is supplied with a radio frequency remote
control. This remote will function up to 20 feet away from
the fireplace.
The heater may emit a slight, harmless odour when first
used. This odour is a normal condition caused by initial
heating of internal heater parts. Thereafter, any odour is
normally the result of household dust settling on the
heater element.
1. Turn the main power on at the control panel.
2. Using the hand held remote, turn the power on at the
remote. If the unit does not turn on, you will need to syn-
chronize the codes.
To synchronize the codes:
Press and hold the on button on the hand held remote.
Press the learn button on the control panel. See CON-
TROL PANEL on page 9. Simultaneously hold both but-
tons in for approximately 5 seconds.
To change the code on the transmitter:
a) Press the button under the battery compartment lid on
the transmitter.
b) Remove the battery from the transmitter and turn "off"
the main power on the control panel.
c) Wait 5 seconds and reinstall the battery and turn "on"
the power.
d) While pressing the "on" button on the hand held re-
mote, press the "learn" button on the control panel. See
CONTROL PANEL on page 9.
e) Hold both in for approximately 5 seconds.
3. To turn the unit off, use either the remote or main power
button on the control panel or the manual on/off button on
the control panel.
4. The thermostat, located on the lower control panel, is
used to control the temperature of the room. To increase
the temperature, turn the dial clockwise.
Bulb Replacement : If you notice the flame look is darker
on one side of the fireplace, check the light bulbs to en-
sure that one has not burned out.
Bulb must be replaced with a MAX 60 watt incandes-
cent clear light bulb.
1. To replace the bulb, turn the circuit breaker off or unplug
the appliance.
2. Open the lower louvres.
3. Detach the light access panel by removing the four
screws.
4. Replace the burned out light bulb using a new 60 watt
clear incandescent bulb.
5. Replace access panel.
6. Turn on the power or plug the appliance back in.
7. Turn on the main power and test.
OPERATION
MAINTENANCE
The flame generator has a random modulating control
which causes the flame effect to speed up and slow down
sporadically. This action creates the realistic flame ap-
pearance and can not be modified.
FLAME EFFECTREMOTE CONTROL