Napoleon Grills GVF36P Indoor Fireplace User Manual


 
12
W415-0297 / D / 04.03.03
Attach the connectors from the
black and red wires to the
blower.
Attach and secure the variable
speed switch using the nut pro-
vided. Plug the harness cord
into the receptacle.
The wire harness provided in this kit is a univer-
sal harness. When installed, ensure that any ex-
cess wire is contained, preventing it from making
contact with moving or hot objects.
Because the blower is thermally activated, when
turned on, it will automatically start approxi-
mately 10 minutes after lighting the fireplace and
will run for approximately 30-45 after the fireplace
has been turned off. Use of the fan increases the
output of heat.
Drywall dust will penetrate into the blower bear-
ings causing irreparable damage. Care must be
taken to prevent drywall dust from coming into
contact with the blower or its compartment. Any
damage resulting from this condition is not cov-
ered by the warranty policy.
INSTALLATION TO BE DONE BY A QUALIFIED INSTALLER
and must be electrically connected and grounded in accord-
ance with local codes. In the absence of local codes, use the
current ANSI/NFPA 70 NATIONAL ELECTRICAL CODE.
If the fireplace was
not previously
equipped with a
blower: route a
grounded 2-wire, 60hz
power cable to the
junction box. At this
point, it must be strain
relieved and insulated.
The three slots on the
blower mounting
bracket allow ease of
adjustment when
attaching the blower. For
a quiet running blower,
do not allow the assem-
bly to sit on the firebox
base.
If optional blower kit is to be installed, remove thermodisc
from the bracket supplied in the kit and disgard the bracket.
Install thermodisc in the bracket supplied with the fire-
place. It is recommended to attach the wires to the disc
and install the bracket before installing the blower. Attach
the black and white wires to the disc, then secure the
bracket to the stud at the bottom left on the unit using the
lock washer and wing nut. Ensure that the thermodisc
touches the firebox wall.
Slide the vibration reducing pad (A) into the clip (C) and up
against the threaded stud (B) at the other end. The blower
must be able to be positioned entirely onto the pad.
Tilt the blower onto its side. Slide it past the controls and
into the clip (C). Secure to the threaded stud using the lock
washer and wing nut provided. Ensure that the blower
does not touch the fireplace base or the firebox.
r
e
d
w
h
i
t
e
b
l
a
c
k
SLOTS
ELONGATED
C
A
B
FIGURES 21
FIGURE 19
FIGURE 20
FIGURE 22
FIGURE 23
OPTIONAL BLOWER INSTALLATION