Napoleon Grills GVF36P Indoor Fireplace User Manual


 
11
W415-0297 / D / 04.03.03
NOTE: ORNAMENTAL INSETS CAN NOT BE USED IN CONJUNCTION
WITH
THE CATALYTIC DOOR
This unique patented catalytic system was designed to
provide unparalleled safety and peace of mind. The top of
the door contains four catalytic tiles which are designed to
filter out combustion gases and limit the carbon monox-
ide output. It is likely that with the fireplace in operation, the
catalytic tiles will actually scrub the carbon monoxide nor-
mally found in the room and reduce it to a lower level. The
tiles must not be altered or removed. They are not field
serviceable and must be tested annually. The hood sup-
plied with the unit must be disgarded and replaced with
the hood designed for use with the catalytic door.
The heater with an optional catalytic door in place must
not be operated when using any products such as paint,
paint thinner, adhesives, etc. These products will perma-
nently affect the catalytic tiles’ ability to scrub the air.
1. The mesh must be removed if the catalytic door is used.
Remove the centre bracket and bend the curtain rod slightly
to disengage the rod from either side.
2. Remove the curtain support plate. Remove the two latch
securing screws, already installed, position latch as shown
in and re-secure with the screws. A ¼” socket ratchet is
recommended for this.
Repeat at the bottom. For location, see .
3. Screw the door hinge onto the heater by first starting
each of the five machine screws and then tightening all
screws.
4. & 5. Secure the door using the two latches.
Install the appropriate hood by hooking it over the top lip of
the door assembly.
The heater must not be used when the hood is removed.
Care must be taken when closing and opening the cata-
lytic door to avoid damaging the catalytic tiles.
DOOR HINGE
3
4
5
BOTTOM DOOR LATCH
5
CAUTION:CAUTION:
CAUTION:CAUTION:
CAUTION:
The m The m
The m The m
The m
inimum clearance to inimum clearance to
inimum clearance to inimum clearance to
inimum clearance to
a combusti-a combusti-
a combusti-a combusti-
a combusti-
bb
bb
b
le mantle is 12” when using a cale mantle is 12” when using a ca
le mantle is 12” when using a cale mantle is 12” when using a ca
le mantle is 12” when using a ca
talytic doortalytic door
talytic doortalytic door
talytic door
..
..
.
OPTIONS
GVF103-KT - PATENTED CATALYTIC
DOOR INSTALLATION
CURTAIN ROD BRACKET
1
FIGURES 18
TOP DOOR LATCH
4
CURTAIN SUPPORT PLATE
LATCH SCREW
LOCATION
2