Multiquip st3020b1 Septic System User Manual


 

1 2 3 4
1 2 3 4
FUSE
L1 L2
L3
L1 L2
L3
X2
XF
X1
H4 H2 H3 H1
110
115
120
X1
GREEN
BLACK
RED
230 VAC
POWER OUTPUT
TO PUMP
EXTERNAL
230VAC, 60 Hz
230/460 VAC, 60 Hz
POWER SOURCE
CIRCUIT
BREAKER
RED
BLACK
L1
L2
GREEN
GROUND
SUBMERSIBLE
PUMP
BLACK
RED
START FLOAT
SWITCH. CONNECT
TO TERMINALS 1 AND 2
STOP FLOAT
SWITCH. CONNECT
TO TERMINALS 3 AND 4
PUMPING
RANGE
SECURE FLOAT SWITCH
WIRES TO PUMP
DISCHARGE HOSE
MOUNT CONTROL
BOX IN AN UPRIGHT
VERTICAL POSITION
AS SHOWN.
FLOAT
SWITCH
INPUTS
ACPOWER
TERMINAL
BLOCK
ELECTRONIC OVERLOAD
UNIT TERMINAL BLOCK
NOTE:
REFER TO OPERATION MANUAL
FOR THE CORRECT SETTING OF
THE ELECTRONIC OVERLOAD UNI
T.
CONTACTOR
WARNING
CONTROL BOXINSTALLATION ISTO BE
PERFORMED BYALICENSED ELECTRICIAN
OR QUALIFIED PERSONNEL.
THE POSSIBILITY OFELECTRICAL SHOCK
OR ELECTROCUTION EXISTS, WHICH COULD
CAUSE SEVERE BODILYHARM EVEN DEATH!.
CHECK JUMPER SETTINGS ON
TRANSFORMER, REFERENCE
CB200 WIRING DIAGRAM. 230 VAC
CONFIGURATION SHOWN.
NOTE:
95
96
97
98
ON
TEST
STOP
8
10
12
18A
RESET
MAN
AUTO
E16DU
TRIPCLASS10
4 T2
NC
NO
6 T3
2 T1
ABB
1L1
3L2 5L3
POWER INPUT
TO CTRL BX.
TERMINAL BD.
POWER INPUT CABLE
TO CONTROL BOX
1L1
3L2
5L3 13NO
2T1
4T2
6T3 14NO
ABB
A16-30-10
A1 A2
FLOATSWITCH
TERMINALBLOCK
WHITE
JUMPER
WIRE
SINGLE
FLOAT SWITCH
APPLICATION
MODEL SW1WOPA
TB1
A
B
NOTICE
For correct wiring to pump motor (1Ø, 230 VAC), add
a 16 AWG. jumper wire approximately 5-inches in
length between the input terminal block marked L3 and
terminal 4 on the electronic overload unit. Reference
CB200 wiring diagram (new style)
Figure 11. CB200 Control Box (New Style)
Dual Float Switch Application Diagram
FLOAT SWITCHES (CONTROL BOX)