6 70D0004
PRODUCT FEATURES AND SPECIFICATIONS
NATURAL GAS
NOTE: An external regulator is required to reduce supply pressure to a maximum of 10
1
/2" W.C. on
natural gas systems operating at higher pressure.
MILLI-VOLT
Regulator Pressure Setting: 3.5" w.c.
Pilot Regulator: 3.5" w.c.
Gas Inlet Pressure: Max 10
1
/2" w.c.
Min. 5" w.c.
PROPANE/LPG
Note: An external regulator is required to reduce supply pressure to a maximum of 13" w.c.
MILLI-VOLT
Regulator Pressure Setting: 10" w.c
Gas Inlet Pressure: Max. 13" w.c.
Min. 11" w.c.
IGNITION CONTROLS
Piezo ignitor allows ignition of the pilot without the use of matches or batteries.
Milli-Volt control has four (4) positions:
OFF - All gas to the gas logs is shut off at the valve.
IGN - Valve position to light/maintain a standing pilot.
ON - Valve position to turn ON/OFF log set with remote switch/thermostat.
LOW/HI - Variable position to control flame height (heat output).
PILOT/ODS
The gas log heater is fitted with a specially designed safety pilot (ODS assembly) which senses the amount of oxygen avail-
able in the room and shuts the gas log heater off if the oxygen level begins to drop below a satisfactory level. The pilot can
only be relit when adequate fresh air is available.
THERMAL GENERATOR
The millivolt gas log pilot is fitted with a milli-volt (thermopile) generator to provide power for remote activation.
Model Number Control
Gas Rate
Max BTU/Hr Min BTU/Hr
TPB18NV Milli-Volt 28,000 19,000
TPB24NV Milli-Volt 38,000 26,000
TPB30NV Milli-Volt 38,000 26,000
Model Number Control
Gas Rate
Max BTU/Hr Min BTU/Hr
TPB18PV Milli-Volt 28,000 23,000
TPB24PV Milli-Volt 34,000 26,000
TPB30PV Milli-Volt 34,000 26,000