Monessen Hearth TPB18 Electric Heater User Manual


 
10 70D0004
PLACEMENT IN A FIREPLACE WITH A RESTRICTIVE BARRIER
IMPORTANT INFORMATION FOR THE INSTALLATION OF THIS GAS LOG SET
The following are guidelines for placing a gas log set in a fireplace that has a restrictive barrier along the bottom front open-
ing of the fireplace. Some examples of barriers are glass/screen door frames and sunken/recessed fireplaces.
Glass door frames
with adjustable
louvers should have
the louvers fully
open while the unit is
in operation.
Height of restrictive barrier
caused by glass door frames,
recessed replaces, etc. from
the base or bottom surface of the
unit. (See Table).
The log set should be
placed against or as near
as possible to the rear wall
of the replace/ rebox.
Depth of replace/ rebox.
(See Table).
Figure 3 - Reference Drawing of a Natural Flame Log Set in an Enclosure
NOTE: Non combustible material such as refractory brick may be used to line the oor of the replace
in order to raise the height of the gas log set in relation to a restrictive barrier. If the unit is raised, the
minimum height dimension listed in the homeowner’s manual must not be exceeded.
NOTE: If the log set is equipped with a remote receiver, a restrictive barrier may reduce the battery life by
increasing the ambient temperature inside the replace. Placement of the receiver outside of the replace
will extend the battery life.
X
Height of Restriction (X) Minimum Depth of Fireplace/Firebox
No restriction 13
1
/ 4"
0 to 1
1
/2" 16"
From 1
1
/2" to 3" 16"
Greater than 3" ANY BARRIER GREATER THAN THREE INCHES (3") PLACED IN FRONT OF
THE GAS LOG SET IS NOT RECOMMENDED BY THE MANUFACTURER.
Barriers such as the bottom of a glass door frame placed in front of a gas log set can
change the air ow characteristics of the replace which in turn can cause the unit to
overheat and malfunction.
WARNING