Monessen Hearth TPB18 Electric Heater User Manual


 
34 70D0004
Note: All troubleshooting items are listed in order of operation.
TROUBLESHOOTING
WARNING
OBSERVED PROBLEM POSSIBLE CAUSE REMEDY
When ignitor button is
pressed, there is no spark at
ODS/pilot.
1. Ignitor electrode positioned wrong. 1 Replace ignitor.
2. Ignitor electrode is broken. 2. Replace ignitor.
3. Ignitor electrode not connected to ignitor
cable.
3. Reconnect ignitor cable.
4. Ignitor cable pinched or wet. Keep ignitor
cable dry.
4. Free ignitor cable if pinched by any metal or
tubing.
5. Broken ignitor cable. 5. Replace ignitor cable.
6. Bad piezo ignitor. 6. Replace piezo ignitor.
Appliance produces
unwanted odors.
1. Appliance burning vapors from paint, hair
spray, glues, etc.
1. Ventilate room. Stop using odor causing
products while heater is running.
2. Gas leak. 2. Locate and correct all leaks.
3. Initial burn off
3. Ventilate room and turn unit on high until odor
is gone. Odor should be gone after 6 hours of
continuous use.
Appliance shuts off during
use.
1. Not enough fresh air is available for ODS/
pilot to operate.
1. Open window and/or door for ventilation.
2. Low line pressure. 2. Contact local gas company.
3. ODS/pilot is partially clogged. 3. Clean ODS/pilot.
4. Defective Thermopile. 4. Check wire connections. Check output should
be 500 milli-volts across TH/TP and TP
Terminals with ON/OFF switches off.
5. Restrictions in incoming air flow. 5. Check for bottom riser on glass door, sunken
fireplace, excessive lava rock/cinders densely
packed against grate.
Gas odor even when control
knob is in OFF position.
1. Gas leak. 1. Locate and correct all leaks.
2. Control valve defective. 2. Replace control valve.
When ignitor button is
pressed, there is spark at
ODS pilot, but no ignition.
1. Gas supply turned off or manual shutoff
valve closed.
1. Turn on gas supply or open manual shutoff
valve.
2. Control knob not in PILOT position. 2. Turn control knob to PILOT position.
3. Control knob not pressed in while in PILOT
position.
3. Press in control knob while in PILOT position.
4. Air in gas lines when installed. 4. Continue holding down control knob. Repeat
igniting operation until air is removed.
5. ODS/pilot is clogged. 5. Replace ODS/pilot assembly or get it serviced.
6. Gas regulator setting is not correct. 6. Check incoming pressure. Replace gas
regulator.
WARNING
Turn appliance OFF and allow to cool before
servicing. Only a quali ed service person
should service and repair the heater.