BBV, SBV Series Natural Vent Gas Fireplaces
SECURE FIREPLACE TO FLOOR OR FRAMING
The fireplace must be secured to
the floor and/or to framing studs
as shown in Figure 5. Use two (2)
wood screws or masonry/con-
crete screws to secure fireplace
to the floor. Use four (4) screws
to attach fireplace to framing.
The side brackets are adjust-
able from 1/2” to 5/8” to accom-
modate different thicknesses of
material.
&0
SECURETOFRAMING

Framing
1/2” Nail
Flange
Screws
Screws
Screws
Framing
1/2” Nail
Flange
1/2” Nail
Flange
1/2” Nail
Flange
5/8” Nail Flange
5/8” Nail
Flange
FP2019
Figure 6 -
Secure Fireplace to Floor and Framing Studs
FINISHING MATERIAL
NOTE: Any remote wiring (i.e. remote control and wall switch) must be done prior to final fin-
ishing to avoid costly reconstruction.
WARNING
Never obstruct or modify
the air inlet. This may create
a fire hazard.
Only noncombustible materials (i.e. brick, tile, slate, steel or other materials with a UL fire rating of Zero)
may be used to cover the black surface of the appliance. A 300° F minimum adhesive may be used to
attach facing materials to the black surface. If joints between the finished wall and the fireplace sur-
round are sealed, a 300° F minimum sealant material (General Electric RTV 103 or equivalent) must
be used.