Monessen Hearth SBV500 Indoor Fireplace User Manual


 
62D4036
4
BBV, SBV Series Natural Vent Gas Fireplaces
CODE APPROVAL
These appliances have been tested by CSA and found to comply with the established standards
for VENTED GAS FIREPACES in the US and Canada as follows:
LISTED VENTED GAS FIREPLACE
TESTED TO: ANSI Z21.50a-2008 CSA2.22a-2008
14. Do not use any solid fuels (wood, coal, paper, card-
board, etc.) in this fireplace. Use only the gas type
indicated on rating plate.
15. This appliance, when installed, must be electrically
grounded in accordance with local codes or in the
absence of local codes, with the National Electri-
cal Code, ANSI/NFPA 70 or the Canadian Electrical
Code, CSA C22.1.
16. Do not obstruct the flow of combustion and ventilation
air in any way. Provide adequate clearances around
air openings into the combustion chamber along with
adequate accessibility clearance for servicing and
proper operation.
17. When the appliance is installed directly on carpeting,
tile or other combustible material other than wood
flooring, you must set appliance on a metal or wood
panel or hearth pad extending the full width and depth
of the appliance.
18. Do not use fireplace if any part has been exposed to
or has been under water. Immediately call a quali-
fied service person to arrange for replacement of the
unit.
19. Do not operate fireplace if any log is broken.
20. Do not use a blower fireplace, heat exchanger fire-
place or any other accessory not approved for use
with this fireplace.
21. The fireplace is not intended for use with a thermo-
stat.
22. This appliance must be installed with draft hood in
same atmospheric pressure zone as the combustion
air inlet to the appliance.
23. For Massachusetts Residents Only: This product
must be installed by a licensed plumber or gas fitter
when installed within the Commonwealth of Massa-
chusetts. Flexline installation must not exceed 36”.
IMPORTANT SAFETY INFORMATION
Continued on Page 4
IMPORTANT:
PLEASE READ THE FOLLOWING CAREFULLY
It is normal for fireplaces fabricated of steel to give off
some expansion and/or contraction noises during the
start up or cool down cycle. Similar noises are found
with your furnace heat exchanger or car engine.
IMPORTANT:
PLEASE READ THE FOLLOWING CAREFULLY
It is not unusual for gas fireplace to give off some odor
the first time it is burned. This is due to the manufactur-
ing process.
Please ensure that your room is well ventilated dur-
ing burn off - open all windows.
It is recommended that you burn your fireplace for at
least en (10) hours the first time you use it.
Never connect unit to private
(non-utility) gas wells. This gas is com-
monly known as wellhead gas.
WARNING
WARNING
Proposition 65 Warning: Fuels listed in gas, wood burning or oil fired appliances,
and the products of combustion of such fuels, contain chemicals known to the State
of California to cause cancer, birth defects and other reproductive harm.
California Health and Safety Code Sec. 25249.6