Monessen Hearth SBV500 Indoor Fireplace User Manual


 
62D4036
25
BBV, SBV Series Natural Vent Gas Fireplaces
CLEANING and MAINTENANCE
VENT SYSTEM
The fireplace and venting system should be inspected before initial use and at least annually by a quali-
fied field service person. Inspect the external vent cap on a regular basis to make sure that no debris is
interfering with the airflow. Inspect entire venting system to ensure proper function.
LOGS
Leave logs installed in the fireplace for cleaning. Vacuum surface of the logs with a brush attachment. If
logs must be removed for cleaning, handle carefully by holding gently at each end. Gloves are recom-
mended to prevent skin irritation from ceramic fibers. If skin becomes irritated, wash gently with soap
and water. Vacuum surface of logs with brush attachment or brush logs with a soft bristle brush (i.e.
clean, dry paintbrush). To place logs back in the fireplace, refer to “Log Placement” found in the Final
Installation section.
NOTE: Do not use cleaning fluid to clean logs.
ROCK WOOL
Replace or add rock wool as required following installation instructions in the Final Installation section
of this manual.