Monessen Hearth LRCF36 Indoor Fireplace User Manual


 
16 79D0004
120VAC
Receptacle
Junction Box
BLACK
GREEN
TANTANWHITEBLACKBLACK
Speed Control
Optional Thermostatic Switch
WIRING TO JUNCTION BOX & GLASS CLEANING
CAUTION
FORCED AIR KIT
If you are installing the forced air kit Model BLOTDL on the LSTF36, LPF36, GCRF36 or GCLF36 units, see the installa-
tion instructions below supplied with kit.
Electrical connections should only be performed by a quali ed, licensed electrician,
main power must be off when connecting to main electrical power supply or
performing service.
The blower when installed, must be electrically grounded in accordance with local
codes or in the absence of local codes, with the National Electrical Code ANSI/NFPA
70.
WIRING TO JUNCTION BOX
NOTE: The wire must be run to the junction box before framing the rebox.
1. Wire the receptacle into an electrical circuit. Use minimum 60°C wire in accordance to prevailing codes.
2. The junction box is preinstalled at the factory. Remove junction box cover by removing the screw from the out
side firebox wall.
3. The junction box cover has a factory-installed “romex” style strain relief connector. Connect the wires according
to the wiring diagram below. Route the connected wire leads through the strain relief connector. See Figure 20.
Figure 20a - Wiring Diagram for Junction
GLASS CLEANING
NOTE: Glass should not be removed for cleaning
When Cleaning Glass
Allow glass to cool before cleaning.
Never use abrasive cleaning materials on glass.
Keep children and pets at safe distance away.
Never operate fireplace if glass is broken. Replace any glass that is chipped, cracked or broken. Replacement
glass frame assemblies MUST be supplied by the fireplace manufacturer. Do not substitute other materials.
Handle glass frame with care. Avoid striking or scratching glass on hard objects.
Figure 20b - Wiring Diagram for Blower
NOTE: For see thru and peninsula
models, two blower kits may be used
and will be controlled independently.