12 79D0004
FIREPLACE INSTALLATION
SEE-THROUGH UNIT (LSTF36) INSTALLATION
1. Attach nailing flanges in desired position. See Figure 16.
3. Slide firebox into prepared framing or position firebox in its final position and frame later.
4. Level and plumb firebox by checking edges of firebox. Shim if necessary.
5. Attach nailing flanges to studs. See Figure 17.
6. Install canopy. Refer to page 15 for canopy installation.
Figure 17 - Location of Nailing Flanges and Floor Screws
Nailing Flange