Monessen Hearth BWBC500MHB Indoor Fireplace User Manual


 
61D0087 23
Fan
Motor
1
Fan
Motor
2
On/Off
Rocker Switch
(SPST)
Cord Set
120V, 60Hz
Fireplace
Receptacle Box
Ground
Field Wire to
60Hz, 120 VAC, 15AMP
Electrical Circuit
12"max.
A
B
This fireplace is equipped with a fan assembly to help circulate heat pro-
duced by the fireplace. The energy used by the fan assembly will be less
than a 30 watt light bulb.
The fan assembly has been factory-wired to the fireplace receptacle box
located on the right side of the fireplace. Connect wiring from the fireplace
receptacle box (field-wired) to a 60 Hz, 120 vac, 15 amp electrical circuit.
Field-wiring must comply with local codes or, in the absence of local
codes, with the latest edition of National Electrical Code ANSI/NFPA 70.
See Figure 26.
Always check and make
sure power is off before
attempting to install or
service any electrical wiring
or components.
WARNING
Figure 26 - Wiring Diagram
Figure 25 - Locating Mantel
LOCATING MANTEL
Maximum depth of mantel is 12"
A = 6½" - Minimum from top of fireplace opening to bottom
of any combustible trim material sticking out no
more than 1½" beyond face of fireplace
B = 12" - Minimum from top of fireplace opening to bottom
of combustible trim material sticking out more than
1½" from top of fireplace opening
Top of
Fireplace
Opening
Combustible
Mantel
Non-
Combustible
Surround Trim
FAN ASSEMBLY
TRIM AND MANTEL INSTALLATION FOR WOOD BURNING FIREPLACES
Combustible
Wall Board