Mitsumi electronic PLA-A24AA Air Conditioner User Manual


 
28
10-7-2. Indoor controller board
PLA-A12AA PLA-A18AA PLA-A24AA PLA-A30AA PLA-A36AA PLA-A42AA
PLA-A12AA1 PLA-A18AA1 PLA-A24AA1 PLA-A30AA1 PLA-A36AA1 PLA-A42AA1
CN2D
Connect to the indoor power board
(CN2S)
(12.5~13.7V DC)
CNDK
Connect to the indoor
power board (CNSK)
(208/230V AC)
FUSE
(6.3 A 250 V)
CN22
Connect to the terminal
block(TB5)
(Remote controller connecting
wire)
(10.4~14.6V DC)
CN21
Pipe temperature
thermistor/Liquid (TH2)
CN20
Room temperature
thermistor (TH1)
CN41
Connector (HA terminal-A)
CN6V
Vane motor output
(MV)
CN90
Connect to the wireless
remote controller board
(CNB)
CN31
Drain sensor (DS)
CN51
Centrally control
CN29
Condenser/evaporator
temperature thermistor (TH5)
CN24
Heater output
(12V DC)
SW1
Model setting
SW2
Capacity setting
SWE
Emergency operation
LED1
Power supply (I.B)
LED2
Power supply (R.B)
LED3
Transmission (Indoor/outdoor)
CN3C
Transmission
(Indoor/outdoor)
(0~24V DC)
FAN
Fan motor output
Jumper wire J41, J42
Pair number setting with
wireless remote controller
CND
Power supply input
(208/230V AC)
CNP
Drain-pump output
(DP)
(208/230V AC)
CN2L
Connector
(LOSSNAY)
CN32
Remote switch
CNC
Dew prevention
heater (H2)
(208/230V AC)
OC370B--1.qxp 07.6.20 2:42 PM Page 28