Thermistor TH2
Pipe temperature (Liquid)
Distributor
with strainer (#50)
Thermistor TH5
(Cond./ Eva. temperature)
Thermistor TH1
(Room temperature)
Refrigerant flow in cooling
Refrigerant flow in heating
Strainer (#50)
Strainer (#50)
Heat exchanger
Refrigerant GAS pipe connection
(Flare)
Refrigerant LIQUID pipe connection
(Flare)
9
REFRIGERANT SYSTEM DIAGRAM
PLA-A12AA PLA-A18AA PLA-A24AA PLA-A30AA PLA-A36AA PLA-A42AA
PLA-A12AA1 PLA-A18AA1 PLA-A24AA1 PLA-A30AA1 PLA-A36AA1 PLA-A42AA1
OC370B--1.qxp 07.6.20 2:42 PM Page 13