Mitsubishi Electronics PE-15MYC Air Conditioner User Manual


 
- 61 -
PEH-7MYA-EU (STANDARD)
CR2
GRAY
X1
X1
C6
3
C6
1
1
3
C7
CH
F3(3.15A)
X1
X2
52C
CZ
30
C7
26
D2
21
T1
S4
26
D1
X2
X3
X1 X2X3
T1
49C
52C
1315
HZ2
TB5
BLUE
CZ2
14
63H
51F2
CZ2
CZ
30
51C
HZ2
C5
C4
MC
1
2
3
BLACK
RED
MF3
WHITE
52C
51C
3
2
1
51F2
WHITE
MF2
RED
RED
WHITE
BLACK
BLACK
BLACK
WHITE
BLACK
WHITE
RED
RED
RED
PUH-7MYC1-EU
PEH-7MYA-EU
PE
3Phase
50Hertz
Power supply,
380 415Volt,
CIRCUIT BREAKER
(FIELD SUPPLY) 100A
TB1
L1
L2
L3
N
OUTDOOR
CR1
52F
FZ
FZ
30
52F
BLUE
51F1
30FZ
CZ1
HZ2
GRAY
GRAY
BLUE
BROWN
RED
C1
C1
4
2
1
SW3(FIELD SUPPLY)
JUMPER
TB4
TB4
7
8
6
Low
Hi
15
15
6
5
C
CZ2
13
14
TB3
14
13
(3.15A)
RED
BLUE
RED
TB2
L
N
5
23
WA
CZ1
51F1
MF1
52F
F2
H
C
(3.15A)
F1
SW1
HEATCOOL
24V
Tr
HZ1
3
TB4
TB4
SWITCH BOX
(FIELD SUPPLY)
1
SW2
24
FZ
HZ1
PE
Single Phase
50Hertz
Power supply,
220 240Volt,
CIRCUIT BREAKER
(FIELD SUPPLY) 15A
240V
220
AC
Auxiliary relay (defrost)
Contactor (fan O/D)
T1
Timer (defrost)
Connector
Run capacitor
(compressor)
Internal thermostat
CZ1, 2
HZ1, 2
C
3
Surge killer
CR1, 2
30CZ, FZ
Compressor motor
Terminal blockTB1 5
F1 3
Over current relay
Fan motor (outdoor)
Contactor (compressor)
Over current relay(fanI/D,O/D)
Contactor (fan I/D)
Crankcase heater
Transformer
Fuse (3.15A)
Fan motor (indoor)
(compressor)
High-pressure switch
Thermostat (defrost)
Auxiliary relay (fan)
Auxiliary relay (compressor)
Auxiliary relay (4-way valve)
Auxiliary relay (check)
Switch (operation mode)
Switch (on)
Switch (Fan Hi-Low)
Thermostat (room temp.)
4-Way valve
C1, C3 7
Note:1.The dotted lines show field wiring.
2.The figure in the parentheses show field supply parts.
3.Color of earth wire is yellow and green twisting.
4.Not specified color of wire is brown.
5.Please remove the jumper wire ( Mark) in the above
diagram if you use the Switch <SW3> at local.
If the Switch <SW3> is not used, the Fan motor
(indoor) drives at high speed.
6.Specification subject to change without notice.
Caution,
1.To protect each Fan motor and Compressor from abnormal
current, Over current relays <51C>, <51F1,2> are installed.
Therefore, do not change factory set value of Over current
relays.
Option controller connection.
FAN HI
4WV
COMP
24VAC(L)
PAC-204RC (Option)
terminal no.
24VAC(N)
2
3
Power (Neutral)
Fan operation
Cooling or Heating
operation
Reversing valve
for Heating operation
Power (Active)
Function
5
4
1
No.
TB3
Symbol
Thermostat (freeze protection)26L
HZ1
3
1
C3
C3
26L