Mitsubishi Electronics PCFY-P24NKMU-E Heat Pump User Manual


 
25
0
5
9
4
8
3
7
2
6
1
0
5
9
4
8
3
7
2
6
1
0
5
9
4
8
3
7
2
6
1
0
5
9
4
8
3
7
2
6
1
0
8
F
7
E
6
D
5
C
4
B
3
A
2
9
1
0
8
F
7
E
6
D
5
C
4
B
3
A
2
9
1
Switch
SWA
Ceiling
height
selector
SWC
Option
selector
Rotary switchRotary switch
SW14
Branch
No.
setting
SW11
1s digit
address
setting
SW12
10ths digit
address
setting
Pole
(High ceiling)
(Standard)
(Silent)
3
2
1
(Option)
(Standard)
1~3
2
Operation by switch
* Ceiling height can be changed depending
on SWA setting.
Remarks
<Initial setting>
Address board
<Initial setting>
Address board
Address can be set while the
unit is stopped.
Address board
<Initial setting>
Address board
3
2
1
SW12
10
SW11
1
SW12 SW11
SW14
SW14
<Initial setting>
Effective
timing
Before
power
supply
ON
Under
operation
or
suspension
Silent
8.2ft.(2.5m)
8.5ft.(2.6m)
Standard
8.9ft.(2.7m)
9.8ft.(3.0m)
High ceiling
11.5ft.(3.5m)
13.8ft.(4.2m)
P15, P24
P30, P36
SWA
* In this model it is not necessary to
change SWC to the option side.
How to set address
Example : If address is "3", remain SW12
(for over 10) at "0", and match SW11 (for 1 to 9)
with "3".
How to set branch number SW14 (Series R2 only)
Match the indoor unit’s refrigerant pipe with the BC
contoller’s end connection number
Remain other than series R2 at "0".