OPERATING PROCEDURE PHOTOS
4. Removing the outdoor fan motor
(1) Remove the screws securing the outdoor fan motor.
(2) Remove the lead clamps.
(3) Disconnect the capacitor terminal and wire of the terminal.
(4) Pull out the outdoor fan motor.
5. Removing the compressor
(1) Remove the lead clamps.
(2) Remove the screws securing the relay panel.
(3) Remove the screw securing the service port.
(4) Remove the terminal cover. (See Photo 7.)
(5) Pull out the lead from the compressor terminal.
(6) Remove the overcurrect relay.
(7) Remove the compressor nuts.
(8) Detach the suction pipe welded section and discharge pipe
welded section with a burner.
NOTE
Before using a burner, purge gas from the pipes until the pres-
sure gauge shows 0 kg/cm
2
.
Use the burner under the condition that gas can be released
even when the inner pressure rises by heat.
Photo 5
Photo 6
Photo 7
Photo 8
Photo 9
Suction pipe
Discharge pipe
Sound proof felt
Compressor nuts
Compressor
Terminal cover
Relay panel
Outdoor fan motor
Outdoor fan motor set screws
Lead
fxture