Section 2 Installation Instructions
2-1
Section 2
Installation Instructions
General
These instructions are provided to assist the qualified
installer. Check your local yellow pages for the name
of the nearest Manitowoc Ice Machine Distributor or
call Manitowoc Ice, Inc. for information regarding
installation and start-up services.
WARNING
Improper installation will affect dispensing rate.
Install only within the parameters outlined in this
installation manual.
Please contact your local Manitowoc Distributor or
call Manitowoc Ice, Inc. for assistance if you
encounter a problem that is not covered by this
manual.
Dimensions
Electrical Service
WARNING
All wiring must conform to local, state, and
national codes.
Voltage/Cycle/
Phase
Runnin
g Amps
N.E.M.A Electrical Plug
Configuration
115/60/1 .3 5-15P
220/240/50/1 .1 No plug attached
115 VOLT WIRING
The 115/60/1 AuCS
has an eight (8) foot cord
which must be plugged into a 15 amp electrical
outlet.
CAUTION
Never use an extension cord. If an outlet is not in
reach of the AuCS
power cord, have an outlet
installed.
220/240 VOLT WIRING
The 220/240/50/1 AuCS
can be wired to:
The terminal block located in the ice machine.
With a separate plug.
To a separate disconnect.
220/240/50/1 Wiring
SV1632G
3.43 "
8.7 CM
12.12"
30.78 CM
9’
274.3 CM
8’
243 CM
12”
30.48 CM
TERMINAL BLOCK LOCATED
IN ICE MACHINE
L
1
L
1
PRE-WIRED TO ICE MACHINE
N N
GROUND
GROUND
TO SEPARATE FUSE/
CIRCUIT BREAKER.
DISCONNECT ALL POLES.
REFER TO ICE MACHINE
INSTALLATION
INSTRUCTIONS FOR
FUSE RATING.
AuCS
®
POWER
CORD
N
L
1
PRE-WIRED AT AuCS
®
ACCESSORY
SV1633G