Manitowoc Ice Q Vacuum Cleaner User Manual


 
Installation Instructions Section 2
2-14
Setting Frequency Of Cleanings
The AuCS
A is factory-set to clean (or sanitize) the
ice machine approximately once every two weeks.
For less frequent cleaning, set the selector switch as
indicated below. (Refer to “Component Location and
Identification” for selector switch location.)
Switch
Position
Time Between
Cleanings
0 No cleaning (OFF)
1
Approximately 2 weeks
(1120 harvests)
2
Approximately 4 weeks
(2240 harvests)
3
Approximately 12 weeks
(6720 harvests)
NOTE: Switch positions 4-9 are inoperative. Do not
use them.
Important
Using the AuCS
A accessory is supplemental to
regular cleaning and sanitizing (per Manitowoc
recommendations and local regulations).
Removal From Service/Winterization
CAUTION
Leaving solutions in the AuCS
A in freezing
temperatures may result in severe damage to the
dispensing pump. A failure of this nature is not
covered by the warranty.
If the AuCS
A is to be removed from service for
extended periods, or if it is to be exposed to ambient
temperatures of 32F (0C) or below, follow this
procedure:
1. Remove the Cleaning or Sanitizing solution
bottle.
2. Follow the instructions under “Hose Priming” to
pump all of the solution out of the dispensing
pump and line.