Majestic Appliances UVSRC42 Indoor Fireplace User Manual


 
9
UVSRC Series Firebox
20002068
Finishing
Refer to Page 5, Figure 3 for allowable finishing materi-
als and clearances to combustibles.
All joints, top, bottom and sides, where the wall or
decorative facing material meets the firebox surround
must be completely sealed with a noncombustible
material. (Figs. 11-14)
NOTE: Do not install combustible materials on any
of the black fireplace surround.
Hearth Extension
A hearth extension may be used but is not required for
these fireboxes.
A raised hearth extension may be used as shown in
Figure 15.
Fig. 11 Sealing spaces between appliance and finishing
materials.
FE107
Noncombustible
Caulking/Insulation
2 x 4
Framing
Finishing MaterialStandoff
Fig. 12 Surround flush with finished wall.
FP568a
¹⁄₂"
See mantel drawing for
shelf-to-surround
dimension
Mantel Shelf
Finished Wall
Stud
2 x 4
Standoff
Seal with noncombustible
material ONLY
Surround
Fireplace
Front
2 x 4 Stud
Finished Wall
May be sealed with
noncombustible material
Fireplace Front
Top View
Side View
Fig. 14 Facing on firebox flush with finished wall.
FP611a
Finished Wall
Noncombustible
Decorative
Facing
Surround
2 x 4 Finished
Header
Covered Wall
Must be sealed with
noncombustible material
Standoff
Hearth
Brick
Hearth
Extension
Surround
Noncombustible
Hearth Extension
Combustible
Platform
FP612b
Fig. 15 Side view of firebox with raised hearth extension.
FP610a
Fig. 13 Appliance surround flush with finished wall.
Finished Wall
Must be sealed with
noncombustible
material
Noncombustible
Decorative Facing
Surround
2 x 4 Finished Header
Standoff