Maintenance
Keep the control compartment, logs and burner area
surrounding the logs clean by carefully vacuuming or
brushing at least twice a year or as necessary.
THE LOGS CAN GET VERY HOT — HANDLE ONLY
WHEN COOL.
Always turn off the gas to the pilot before cleaning. For
relighting, refer to the lighting instructions located on
the Rating Plate of the gas log set.
Never obstruct the flow of combustion and ventilation
air. Keep the front of the appliance clear of all obstacles
and materials.
Leave at least a 36" clearance from the front of the
firebox to any room furnishings.
Install Hood
A hood is furnished with the firebox. Optional hoods
listed on Page 12 may be installed as shown in Figures
16 and 17. Failure to do so may create a fire hazard.
WARNING: When the black surround is covered by a
brick surface, (Figure 16), use an extended hood. The
hood should extend out to the brick surface (Figures 16
and 17) and be attached to the firebox. The maximum
brick to noncombustible surface that may extend out
past the black surround surface is 4¹⁄₄".
Fig. 16 Side view of firebox with extended hood.
FP612a
4¹⁄₄" Max.
Brick Surface
Extended Hood
Fig. 17 Hood location.
FP613a
Screw
(Fastens to side rail
from inside hood)
Use
Bottom
Slot
Slot
Screw
Top of Fireplace
Surround