Lux Products PSP711TS Thermostat User Manual


 
10
W Y G B O RC RH C
2 WIRE 24 VOLT/MILLIVOLT SYSTEM
24 VOLT
HEAT
TRANSFORMER
120 VAC
HEAT
SYSTEM COMMON
OPTIONAL
RC-RH
JUMPER PROVIDED
W Y G B O RC RH C
3 WIRE HEATING SYSTEM (3RD WIRE FOR FAN)
24 VOLT
HEAT
TRANSFORMER
120 VAC
FANHEAT
SYSTEM COMMON
OPTIONAL
RC-RH
JUMPER PROVIDED
W Y G B O RC RH C
3 WIRE COOLING SYSTEM
24 VOLT
COOL
TRANSFORMER
120 VAC
AC
COMPRESSOR
FAN
SYSTEM COMMON
OPTIONAL
RC-RH
JUMPER PROVIDED
WIRING DIAGRAM
NOTES
(APPLIES TO ALL
DRAWINGS)
* Verify whether “C”,
“X” or “B” wires are
connected to system
common.
* If “B” and “O” are
both present, it is likely
that “B” is a system
common.
* If a “B” wire in your
system is a common,
then connecting it to
the “B” terminal may
cause damage to your
system.
* If “Y” and “C” are
both present, it is likely
that “C” is a system
common.
* Use an optional
common wire to allow
the system to power
your thermostat.
11
W Y G B O RC RH C
4 WIRE HEATING AND COOLING SYSTEM
24 VOLT
SYSTEM
TRANSFORMER
120 VAC
AC
COMPRESSOR
FANHEAT
OPTIONAL
SYSTEM COMMON
RC-RH
JUMPER PROVIDED
W Y G B O RC RH C
5 WIRE SYSTEM HEATING AND COOLING - 2 TRANSFORMERS
24 VOLT
HEAT
TRANSFORMER
120 VAC
24 VOLT
COOL
TRANSFORMER
120 VAC
FANCOOLINGHEAT
OPTIONAL
SYSTEM COMMON
RC-RH
JUMPER REMOVED
W Y G B* O* RC RH C
SINGLE STAGE HEAT PUMP SYSTEM
24 VOLT
SYSTEM
TRANSFORMER
120 VAC
CHANGEOVER
HEAT
CHANGEOVER
COOL
*"B" OR "O" BUT NEVER BOTH
FAN
HEAT
PUMP
ADD
JUMPER
SYSTEM COMMON
OPTIONAL
RC-RH
JUMPER PROVIDED