Lux Products PSP711TS Thermostat User Manual


 
12
WARNING: Use Energizer
®
or DURACELL
®
Alkaline Batteries Only.
Energizer
®
is a registered trademark of Eveready Battery Company, Inc.
DURACELL
®
is a registered trademark of The Gillette Company, Inc.
DAY
MON
MORN
DAY
EVE
NIGHT
MORN
DAY
EVE
NIGHT
MORN
DAY
EVE
NIGHT
TUES
WED
PERIOD
HEAT
TIME TEMP. TIME TEMP.
COOL
DAY
THURS
MORN
DAY
EVE
NIGHT
MORN
DAY
EVE
NIGHT
MORN
DAY
EVE
NIGHT
MORN
DAY
EVE
NIGHT
FRI
SAT
SUN
PERIOD
HEAT
TIME TEMP. TIME TEMP.
COOL
5.2. PROGRAMMING THE UNIT
To ease reprogramming later, record your thermostat’s
programs and settings in the table provided below.
GAS
ELEC
1 2 3 4
ON
12hr
24hr
1U4
SR=OFF
SR=ON
2
F
C
3
5min
2min
4
GAS/ELECTRIC
JUMPER
OPTION
SWITCHES
CRHRCOBGYW
+--
HARDWARE
RESET
OPTION SWITCH
POSITION TABLE
BATTERY COMPARTMENT
SOFTWARE
RESET
JUMPER AND SWITCH POSITIONS
REAR OF THERMOSTAT WITH COVER REMOVED
1.
FEATURES
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
2.
COMPATIBILITY
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
3.
INSTALLATION
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
3.1.
TOOLS REQUIRED
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
3.2.
LOCATION
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
3.3.
REMOVING THE OLD THERMOSTAT
. . . . . . . . . . . . . . . . . . . . . . . 3
3.4.
MOUNTING THE PSP711TS
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
3.5.
CONNECTING THE WIRES
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
3.6.
WIRING DIAGRAMS
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-11
3.7.
COMPLETING YOUR INSTALLATION
. . . . . . . . . . . . . . . . . . . . . . . 3
4.
OPERATING INSTRUCTIONS
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
4.1.
SYSTEM MODE SWITCH
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
4.2.
FAN MODE SWITCH
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
4.3.
UP/DOWN ARROW CHANGE KEYS
. . . . . . . . . . . . . . . . . . . . . . . . 4
4.3.1. TEMPERATURE ADJUSTMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
4.3.2. CHANGING OTHER SETTINGS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
4.4.
NAVIGATION KEYS
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
4.5.
DISPLAY ILLUMINATION
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
4.6.
AUDIBLE BEEP
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
4.7.
ICONS
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
4.7.1. FLAME ICON . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
4.7.2. SNOWFLAKE ICON . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
4.7.3. LOW BATTERY ICON . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
4.8.
HARDWARE RESET
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
4.9.
SOFTWARE RESET
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
4.10.
SETTING THE TIME AND DAY
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
4.11.
TEMPORARY TEMPERATURE OVERRIDE
. . . . . . . . . . . . . . . . . . . 5
4.12.
TEMPERATURE HOLD
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
5.
PROGRAMMING
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
5.1.
DEFAULT ENERGY STAR
®
TEMPERATURE PROGRAMS
. . . . . . 5
5.2.
PROGRAMMING THE UNIT
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
5.2.1.
COPY
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
6.
ADVANCED FEATURES
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
6.1.
FILTER USAGE MONITOR
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
6.2.
SWING SETTING
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
6.3.
TEMPERATURE CALIBRATION
. . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
6.4.
ENERGY USAGE MONITOR
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
6.5.
PROGRAM LOCK
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
6.5.1. TO SET CODE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
6.5.2 TO LOCK SETTINGS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
6.5.3. TO UNLOCK SETTINGS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
7.
SETUP OPTIONS
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
7.1.
THE DISPLAY FORMAT 12/24 SWITCH #1
. . . . . . . . . . . . . . . . . . 7
7.2.
SMART RECOVERY SWITCH #2
. . . . . . . . . . . . . . . . . . . . . . . . . . . 7
7.3.
TEMPERATURE DISPLAY FORMAT F°/C° SWITCH #3
. . . . . . . 8
7.4.
5 MIN/2 MIN MINIMUM RUN TIME SWITCH #4
. . . . . . . . . . . . . 8
7.5.
REPOSITIONING SWITCHES
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
7.6.
GAS/ELECTRIC JUMPER
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
8.
BATTERIES AND MAINTENANCE
. . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
9.
TECHNICAL ASSISTANCE
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
10.
WARRANTY
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
SMART TEMP ELECTRONIC THERMOSTAT
INSTALLATION AND OPERATING INSTRUCTIONS
Mt. Laurel, New Jersey 08054, USA
www.luxproproducts.com
PSP711TS SERIES
43379
Choose Heat or CoolSet Day & Time
Installs Easily
Easy as
123
Please read all instructions carefully before beginning
installation. Save them for future reference.
Before removing any wiring from your existing thermostat,
its wires must be labeled with their terminal designations.
Ignore the color of the wires since they may not comply
with any standard.
IMPORTANT!
Thank you for your confidence in our product. To obtain the best
results from your investment, please read these instructions and
acquaint yourself with your purchase before installing your new
thermostat. Then follow the installation procedures, one step at a
time. This will save you time and minimize the chance of
damaging the thermostat and the systems it controls.
These instructions may contain information beyond that required
for your particular installation. Please save for future reference.
WARNING: Use Energizer
®
or DURACELL
®
Alkaline Batteries Only.
Energizer
®
is a registered trademark of Eveready Battery Company, Inc.
DURACELL
®
is a registered trademark of The Gillette Company, Inc.