LOREX Technology WA-410 Home Security System User Manual


 
Press 1 to change the Install code menu.
Setting : Change Code
1 – Install : 1 2 3 4 5
Press 2 to change the Master code menu.
Setting : Change code
2 – Master : 1 3 5 2 4 6
3.2: Sequence Programming Menu
This menu for code learning establishes a link between all sensors/other wireless
devices and the main console. The main console has to learn the code for all
sensors/other wireless devices and set a sequence learning order, as well as assign the
zone for all programmed sensor/accessory devices. The system can be programmed for
up to 63 devices. It is recommended that the sequence learning order number be
marked on the individual wireless device and recorded in the ‘Summary of Sensors and
Zones Settings”, so that the user can replace/clear the wireless device if it’s required
In the system menu,
SYS_OPTS: 0-SYS_OPTS
1 – SEQ 2 – REPLAC 3 – CLR
Press 1 to go into the sequential programming mode
Sequential Pgming
Trigger Sensor 01
(01 sequence learning order)
The method for sensors learning:
1. PIR Motion Detector :
Install the Battery and select the Power Switch position from OFF to C
position. PIR sensor LED will light for 1 Sec. This means that the sensor
will
transmit a 1sec signal. You can also move in the front of the PIR. It will
detect
your movement and transmit a 1 sec signal. The sensor will “learn” into the
main console.
2. Door / Window Detector :
Install the Battery and let the magnetic switch go from a close position to
an
open position. The LED will light for 1 Sec. The sensor will “learn” into the
main console.
3. Remote Control handset :
Install the Battery and press the PANIC button. The LED will light for 1
Sec. The sensor will “learn” into the main console.
4. Smoke Detector :
Install the Battery and press the S1 button. The LED will light for 1 Sec.
The sensor will “learn” into the main console.
5. Gas Detector :
Plug-in the AC power and press the TEST button. The LED will light for 2
Sec. The sensor will “learn” into the main console.
6. When the sensor is ‘learned” into the main console, it will show the message
10