Linksys SS210 Stove User Manual


 
7
A
B
D
L
†E
†E
K
C
H
I
J
Floor Protection
FLOOR PROTECTION
I
M
F
F
T
Floor
Protection
G
G
K
48”
Max.
Depth
Diagram C: Top View
Corner Clearance, Stove and Flue to Wall
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
6” Ø Flue Collar
PIPE INSTALLATION A
B (1)
C
D (1)
E†
F (1,4)
Single Wall Residential
USA-16”
CAN-483mm
13-3/4”
349mm
USA-24”
CAN-635mm
14-1/2”
368mm
8”
200mm
9”
229mm
Single w/ Pipe
Shield
Residential
USA-10”
CAN-330mm
7-3/4”
197mm
USA-24”
CAN-635mm
14-1/2”
368mm
8”
200mm
9”
229mm
Double Wall Residential or
Mobile Home*
USA-10”
CAN-330mm
7-3/4”
197mm
USA-18”
CAN-483mm
8-1/2”
216mm
8”
200mm
6”
152mm
Double Wall
Alcove
USA-10”
CAN-330mm
7-3/4”
197mm
USA-21”
CAN-559mm
8-1/2”
216mm
8”
200mm
6”
152mm
PIPE INSTALLATION G (4)
H (2) I (6) J (2) K L (5)
Single Wall Residential or Alcove USA-18”
CAN-533mm
USA-37-3/4”
CAN-1213mm
USA-51”
CAN-1422mm
USA-34-3/4”
CAN-1048mm
USA-16”
CAN-450mm
USA 0"
CAN-200mm
Single w/ Pipe
Shield
Residential or Alcove USA-18”
CAN-533mm
USA-37-3/4”
CAN-1213mm
USA-45”
CAN-1270mm
USA-34-3/4”
CAN-1048mm
USA-16”
CAN-450mm
USA 0"
CAN-200mm
Double Wall
Air-Cooled
Residential or Alcove
or Mobile Home*
USA-15”
CAN-450mm
USA-37-3/4”
CAN-1213mm
USA-45”
CAN-1270mm
USA-34-3/4”
CAN-1048mm
USA-16”
CAN-450mm
USA 0"
CAN-200mm
Double Wall
Alcove
N/A
USA-37-3/4”
CAN-1213mm
USA-45”
CAN-1270mm
USA-34-3/4”
CAN-1048mm
USA-16”
CAN-450mm
USA 0"
CAN-200mm
Installation Clearances - Refer to Diagrams A, B and C
Footnotes:
1- These dimensions to the stove body are
for reference only. Actual distances should
be measured from the stove’s flue collar.
2- Minimum noncombustible hearth pad
dimensions.
3- Shield shall be attached to the rear of the
stove pipe with a 1” air space and must run
from the top of the stove to the ceiling.
4- Not applicable to alcove installations.
5-
In corner applications, when installed
at minimum back wall clearances, the
required floor protection is dimensioned
off the back plane of the stove, therefore
the floor protection required off the back
corners (at a 45 degree angle) only needs
to extend to the wall. This situation will
only occur in CANADA installations.
6- Reference dimension only, to assist in
planning the installation.
Clearances to connector pipe shall be mea-
sured from the flue collar of the stove.
USA=8" (200mm) from door opening, Canada=8"
(200mm) from sides and back of unit
u
Dimensions to Stove Body
* Mobile Home - USA only
Diagram A: Top View-Parallel Installation
Diagram B: Side View-
Alcove and Parallel
Installations
PIPE INSTALLATION M
T (6)
Single Wall Residential or Alcove 84”
2134mm
USA-61-3/4”
CAN-1619mm
Single w/ Pipe
Shield
Residential or Alcove 84”
2134mm
USA-61-3/4”
CAN-1619mm
Double Wall
Air-Cooled
Residential or Alcove
or Mobile Home*
72”
1829mm
USA-57-1/2”
CAN-1727mm
Double Wall
Alcove
72”
1829mm
USA-57-1/2”
CAN-1727mm