506052−01 11/09
Page 24
Reconfiguring a system − Page 2 of 2
While reconfiguring, the thermostat will have retained settings from the
previous configuration. If a device has been replaced and re−configura-
tion has detected its replacement device, it will know the original device
is missing and prompt the installer (figure 40).
If this is the initial configuration, the Compatible device found" screen
does not appear.
Missing
(DEVICE ETN)
Model No.(control model no.)
Serial No. (control serial no.)
Found Compatible
(DEVICE ETN)
Model No.(control model no.)
Serial No. (control serial no.)
next
setup HELP
Settings were not copied
Figure 40. Compatible device found
Press next to accept the device and write the thermostat’s settings from
the previous configuration to the found compatible device. The display
changes to Settings were copied". Press next to advance to the next
screen.
Figure 41 lists all communicating devices found and gives you an oppor-
tunity to review the reconfigured devices. Use the arrow buttons to scroll
through the list of items found on the left of the screen. Press about to
highlight an option on the right side of the screen and view details about
that device. If necessary, change SYSTEM settings as described on
Page 10.
HP
XP19−060−230−
06
5809c00015
AIR HANDLER
CBX32MV−60
5809B00020
THERMOSTAT
49W95
A109B00139
SYSTEM
setup HELP
about
next step
back
view/ edit selected device’s
settings
system devices
edit
reset all
Figure 41. System devices screen
Press next step to continue to test the system (see Page 14).