Troubleshooting Tips (Continued)
If . . . Then . . .
Cooling system
does not turn on.
D Set the system to Cool by pressing the
SYSTEM key.
D Check the cool temperature setting to be
sure it is set below the room temperature
and Cool On" is displayed solidly on the
screen.
D Check the circuit breaker to make sure it
is not tripped.
D Check the power switch at the heating
and/or cooling system to make sure it is on.
D Check the furnace door to make sure it
is closed securely.
D Wait five minutes for the cooling system
to respond.
D If the problem has not been identified
and corrected, contact a qualified service
technician.
Cannot set System
setting to Cool.
Check Installer Set−Up Number 170: Heating
and/or Cooling Type*. Make sure the setting
matches the installed heating and/or cooling
system.
"Heat On" is not dis-
played on the
screen.
Set the System setting to Heat and set the
temperature setting above the room temper-
ature. If Heat On" is shown solidly in the
display, but the heating system does not turn
on, see Heating system does not turn on"
suggestions on the previous page.
"Cool On" is not dis-
played on the
screen.
Set the System setting to Cool and set the
temperature setting below the room temper-
ature. If Cool On" is shown solidly in the
display, but the cooling system does not turn
on, see Cooling system does not turn on"
suggestions at the top of this page.