Lennox International Inc. SLP9801 Thermostat User Manual


 
icomfort Wi-Fit 7−Day Programmable Communicating Thermostat
Page 17
Adjust a setting... Configure Dehumidification (no dehumidifying device installed)
(skip if default Basic" dehumidification mode is desired)
edit
about
To adjust a setting, highlight it,
then press Edit
reinstall
next
back
edit
reset
Dehumidification Control Mode
current value:
back
Display Only
Display Only Basic
Precision
Select one
Dehumidification Control Mode
cancelsave
3b
3a
edit
reset
back
Dehumidification Control Mode
current value:
Precision
9:39 am Aug 15, 2012
please view and save all
red settings
Pre−adjustment REQUIREMENTS:
1st, NO physical dehumidification device has been installed.
2nd, configure the thermostat for dehumidification as follows:
1. In the system devices" list, use the arrows (1a) to highlight System.
Press edit (1b).
2. In the System" list, use the arrows (2a) to highlight Dehumidification
Control Mode. The current value defaults to Display Only. Press edit
(2b).
3. Touch one of the radio buttons (3a) to select the mode of dehumidification
control; press save (3b).
4. Use arrows (4a) to highlight any red colored text in the list (e.g. select Min
Dehumidification Setpoint). Press edit (4b).
5. Use arrows (5a) to make changes; press save (5b). Change other red
settings (e.g. Auto Changeover − Humidif. Deadband) using a similar
process.
6. Press the back button to return to Adjust a setting..." screen.
NOTE − If the defaults are correct, you do not have to make any changes, but you
must press save (5b). When all red text is gone, the back button will appear; press it
to return to the Add or Remove Non−communicating equipment?" screen.
1a
1b
2a
2b
4a
4b
System
Staged Delay Timers
Balance Point Control
Dehumidification Control Mode
Humidification Control Mode
Auto Changeover − Humidif. Deadband
Max Humidification Setpoint
Min Dehumidification Setpoint
OK/Humid Boundary
Outdoor Temperature Reading
System Devices
System
Furnace
Thermostat
2 Stage AC Unit
Power (120VAC) Humidifier
System
2nd Stage Differential
Staged Delay Timers
2nd Stage Delay
Dehumidification Control Mode
Humidification Control Mode
OK/Humid Boundary
Outdoor Temperature Reading
System
Min Dehumidification Setpoint
Range is 40 to 60
Default is 45, inc:1
cancelsave
set−to
45
5a
5b
6
Figure 16. Adjust dehumidification when not using Humiditrol or an auxiliary dehumidifier