Table 3. Adjustable Parameters Table (Installer)
Parameter Name: Default Parameter Value Setting Increment Installer entry
System (Go to equipment button and scroll to System) NOTE − All of the following changes are made on the stat.
Equipment Name Ċ (keyboard input screen) Ċ
Filter 1 Timer Selection Calendar Time Calendar Time, Run Time Ċ
Filter 2 Timer Selection Calendar Time Calendar Time, Run Time Ċ
UV Bulb Timer Selection Calendar Time Calendar Time, Run Time Ċ
Humidifier Pad Timer Selection Calendar Time Calendar Time, Run Time Ċ
PureAirt Timer Selection Calendar Time Calendar Time, Run Time Ċ
Smooth Setback Recovery Enabled Enabled, Disabled Ċ
Auto Changeover − Temp Deadband 5ºF 3 to 9ºF 1ºF
Electric Heat Control Mode Standard Standard, Even Heat Ċ
Gas Heat Control Mode: (SLP98, G71MPP) Load Tracking Load Tracking Variable Capacity, Variable Capacity, Staged Ċ
(SL280, EL296) Staged Staged only Ċ
Max Heat Setpoint 90ºF 40 to 90ºF 1ºF
Min Cool Setpoint 60ºF 60 to 99ºF 1ºF
Heat Cool Stages Locked In Disabled Enabled, Disabled Ċ
*1st Stage Differential 1.0ºF 0.5 to 3ºF 0.5ºF
*2nd Stage Differential 1.0ºF 0.5 to 8ºF 0.5ºF
*3rd Stage Differential 0.5ºF 0.5 to 8ºF 0.5ºF
*4th Stage Differential 0.5ºF 0.5 to 8ºF 0.5ºF
*5th Stage Differential 0.5ºF 0.5 to 8ºF 0.5ºF
*6th Stage Differential 0.5ºF 0.5 to 8ºF 0.5ºF
Stage Delay Timers Enabled Enabled, Disabled Ċ
*2nd Stage Delay 20 Minutes 5 to 120 Minutes 5 Min
*3rd Stage Delay 20 Minutes 5 to 120 Minutes 5 Min
*4th Stage Delay 20 Minutes 5 to 120 Minutes 5 Min
*5th Stage Delay 20 Minutes 5 to 120 Minutes 5 Min
*6th Stage Delay 20 Minutes 5 to 120 Minutes 5 Min