BLOWER DATA
SLP98DF090V48C BLOWER PERFORMANCE (less lter)
HEATING BLOWER PERFORMANCE
Heating Adjust CFM Selections
Heating Input Range and Blower Volume - CFM
35% 40% 50% 60% 70% 80% 90% 100%
Increase (+15%) Heat CFM 723 790 925 1060 1195 1329 1464 1599
Increase (+7.5%) Heat CFM 690 752 878 1004 1129 1255 1381 1507
Default Heat CFM 656 714 831 948 1064 1181 1297 1414
Decrease (-7.5% ) Heat CFM 601 654 761 867 974 1081 1188 1295
Decrease (-15% ) Heat CFM 545 593 690 787 884 981 1078 1175
The effect of static pressure is included in air volumes shown.
The following control congurations are available. See Installation Instructions for details and DIP switch settings.
Heat Modes Available (Heating Blower Performance Table):
Single stage thermostat:
- 35%, 70%, 100% input (three-stage) with time delays in-between
Two-stage thermostat:
- Variable Rate Capacity Mode - furnace automatically adjusts ring rate based on rst- and second-stage cycle times
- W1 demand at 70% input, W2 demand at 100% input. No delay between stages
icomfort Touch™ Communicating Thermostat:
- Variable Rate Capacity Mode - furnace automatically adjusts ring rate based on rst- and second-stage cycle times
- 35%, 60%, 80%, 100% (four-stage) with time delays in-between
Cool Mode Available (Cooling Blower Performance table):
First stage COOL (two-stage air conditioning units only) is approximately 70% of the same second stage COOL speed position.
Continuous Fan speeds are approximately 28%, 38%, 70% and 100% (DIP switch selectable) of the same second-stage COOL speed position
minimum 300 cfm.
Lennox Harmony III™ Zoning System Applications - Minimum blower speed is 380 cfm (SLP98DF090V48C) and 450 cfm (SLP98DF090V60C).
COOLING BLOWER PERFORMANCE
Cooling Adjust CFM
Selections
Blower Speed Selections
First Stage Cool Speed - cfm Second Stage Cool Speed - cfm
Low Medium-
Low
Medium
High
High
(Default)
Low Medium-
Low
Medium
High
High
(Default)
Increase (+10%) Cool CFM 775 940 1100 1255 1120 1340 1535 1745
Default Cool CFM 690 875 975 1135 1000 1220 1425 1625
Decrease (-10%) Cool CFM 635 755 915 1025 920 1100 1270 1470
SLP98DF090V60C BLOWER PERFORMANCE (less lter)
HEATING BLOWER PERFORMANCE
Heating Adjust CFM Selections
Heating Input Range and Blower Volume - CFM
35% 40% 50% 60% 70% 80% 90% 100%
Increase (+15%) Heat CFM 653 728 877 1027 1176 1326 1475 1625
Increase (+7.5%) Heat CFM 603 673 813 953 1092 1232 1372 1512
Default Heat CFM 553 618 748 878 1009 1139 1269 1399
Decrease (-7.5% ) Heat CFM 510 570 690 811 931 1051 1171 1292
Decrease (-15% ) Heat CFM 467 522 632 743 853 963 1074 1184
COOLING BLOWER PERFORMANCE
Cooling Adjust CFM
Selections
Blower Speed Selections
First Stage Cool Speed - cfm Second Stage Cool Speed - cfm
Low Medium-
Low
Medium
High
High
(Default)
Low Medium-
Low
Medium
High
High
(Default)
Increase (+10%) Cool CFM 1110 1265 1395 1600 1600 1750 1965 2130
Default Cool CFM 1000 1145 1275 1445 1445 1625 1805 1975
Decrease (-10%) Cool CFM 885 1060 1145 1265 1265 1445 1645 1805