8 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE
Figure 3 - Wall Fixing Template
FPO
After having selected the final mounting position of the appliance, taking
into account the site requirements as specified in these instructions,
the integrity of the wall, and the feasibility of the proposed supply pipe
routing, the firebox of appliance may be secured to the wall.
12.0 MOUNTING THE APPLIANCE
WARNING
The wall where the appliance is to be installed must
be capable of long-term support of the total load of
the appliance. Measures should also be taken to
ensure sufficient strength to withstand the force of
earthquakes, vibration and other external forces.
Incorrect installation can cause the appliance to fall from the wall and
cause injury. Do not block the ventilation holes of the appliance. The
wall onto which the appliance is installed must be flat. Install only on a
vertical surface. Avoid sloped surfaces. Installation onto anything other
than a vertical wall may result in fire, damage or injury.
A full size fitting template is supplied to assist with wall mounting. (see
Figure 3).
If the heater is to be installed on a studded wall with conventional 16”
stud spacing then a wall mounting plate is supplied to enable this. NOTE:
THIS APPLIANCE MUST BE SECURED DIRECTLY TO THE STUDS AT THE
FIXING POINTS THAT ARE 16" DISTANCE (see template below). First
locate the studs and using suitable fixings, screw the mounting plate to
the wall via the four mounting holes. The heater may then be hung onto
the mounting plate. The bottom of the heater may be secured onto the
lower mounting studs using the wing-nuts or the hex nuts provided.
Mark the positions shown as “Fixing Points” on the wall. If the appliance
is to be mounted on the inner leaf of a conventional cavity wall, or a solid
wall, drill four holes using a 5/16" masonry bit, to a depth of 1-11/16".
Insert the fiber wall plugs provided.
If the appliance is to be mounted on a dry lined wall or a timber framed
construction wall then special cavity screw fixings will be required
which are not supplied with this product. These should be constructed
from metal and not plastic.
If a concealed gas connection is to be made ensure the gas supply pipe
is in it’s final position and can enter the appliance in the correct position
when the appliance is hung on the wall.
To ensure customer safety, be sure to design the installation so that the
strength of both the wall and any wall fixings used are sufficient. Lennox
Hearth Products assumes no responsibility for injuries and damages
that may occur due to improper installation or handling.
The appliance should not be installed until all dry wall sanding and wall
painting has been completed.
WARNING
CLEARANCES FROM COMBUSTIBLE MATERIALS
F860041/A
The following clearances must be maintained at all times.
Failure to do so may result in the risk of a fire.
For full information refer to the instruction manual
provided with the heater.
Note : Zero clearance from bottom of heater frame
required for hard combustible floors. Minimum 4”
clearance required to rugs or any fabric floor
coverings. REFER TO INSTRUCTION MANUAL
IMPORTANT : Fabrics, curtains and drapes are not
permited above the heater at any distance and within
20” of the heater sides. No combustible shelves of any
size are permitted above the heater.
Clearance to
combustible
sidewalls 4”
(both sides)
Clearance to combustible ceiling
32” measured from top of appliance
glass panel
Clearance in
front of
heater 20”
F860041/A
Deben mantenerse en todo momento los siguientes espacios
libres. El no hacerlo puede causar un riesgo de incendio.
Consulte el manual de instrucciones suministrado con este
aparato para obtener información completa.
Nota: No se requiere espacio libre desde el borde inferior del
marco del calentador en caso de pisos combustibles duros.
Se requiere un espacio mínimo de 4” entre el calentador y
cualquier alfombra, moqueta o revestimiento de suelo de
tela. CONSULTE EL MANUAL DE INSTRUCCIONES.
IMPORTANTE: No se permite la colocación de telas, cortinas y
similares por encima del calentador a cualquier distancia, ni a
una distancia de 20” de los laterales del calentador. No se
permiten estantes combustibles de cualquier tamaño por
encima del calentador.
Espacio hasta
paredeslaterales
combustibles
4” (ambos lados)
El espacio de 32” hasta un techo
combustible se mide desde el borde
superior del panel de vidrio del aparato
Espacio libre
delante del
calentador 20”
ADVERTENCIA
ESPACIO LIBRE HASTAMATERIALES COMBUSTIBLES
CENTRE LINE
LINEA DE CENTRO
WALL MOUNTED VENT FREE FITTING TEMPLATE
PLANTILLA PARA LA INSTALACION DE CHIMENEAS DE PARED SIN SALIDA DE HUMOS
IMPORTANT
THIS APPLIANCE IS TO BE WALL HUNG ONLY.
DO NOT RECESS OR INSET ANY PART OF THE APPLIANCE.
THIS TEMPLATE IS FOR THE MARKING OF FIXING POINTS ONLY.
DO NOT INSTALL THE APPLIANCE WITH THIS TEMPLATE IN PLACE.
IMPORTANTE
ESTE APARATO UNICAMENTE DEBE SER COLGADO EN UNA PARED.
NO EMPOTRE NINGUN ELEMENTO DE ESTE APARATO.
ESTA PLANTILLA SIRVE UNICAMENTE PARA MARCAR LOS PUNTOS DE FIJACION.
RETIRE LA PLANTILLA ANTES DE COLOCAR LE APARATO.
F860488 - ISSUE A - PRW
CONCEALED
GAS INLET
ENTRADA DE
GAS OCULTA
16” (406mm)
8
3
/4” (223mm) 8
3
/4” (223mm)7
3
/16” (183mm) 7
3
/16” (183mm)
16” (406mm)
FIREBOX OUTLINE
CONTORNO DE LA CAMARA DE COMBUSTION
POSITION SPIRIT LEVEL ALONG THIS EDGE TO LEVEL TEMPLATE BEFORE MARKING OUT WALL
COLOQUE EL NIVEL SOBRE ESTE BORDE PARA NIVELAR LA PLANTILLA ANTES DE MARCAR LA PARED
APPLIANCE OUTLINE CONTORNO DE LA APARATO
PIERCE TEMPLATE TO MARK HOLE POSITION ON WALL X 4
FIXING POINTS
PERFORE LA PLANTILLA PARA MARCAR LA POSICION DE LOS 4 TALADROS EN LA PARED
PUNTOS DE SUJECION
14
1
/2” (368.5mm)14
1
/2” (368.5mm)
1
1
/8”
(29mm)
FocalPointFires Single 26/06/08 F860488 Lennox Widescreen fitting template Artwork Size: W1385 x H651
™
X-FIRES WIDESCREEN