Lennox Hearth MPB3530CNE-B Indoor Fireplace User Manual


 
26
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION
MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
A. This appliance is equipped with an ignition device which
automatically lights the pilot. Do not try to light the pilot
by hand.
B. BEFORE OPERATING smell all around the appliance area
for gas. Be sure to smell next to the floor because some
gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electric switch; do not use any phone
in your building.
FOR YOUR SAFETY READ BEFORE OPERATING
Immediately call your gas supplier from a neighbor’s
phone. Follow the gas supplier’s instructions.
If you cannot reach your gas supplier, call the fire depart-
ment.
C. If any portion of this appliance does not operate as the
instructions indicate, do not try to repair it, call a qualified
service technician. Do not use tools. Force or attempted
repair may result in a fire or explosion.
D. Do not use this appliance if any part has been under
water. Immediately call a qualified service technician
to inspect the appliance and to replace any part of the
control system and any gas control which has been under
water.
OPERATING INSTRUCTIONS — ELECTRONIC
1. For complete shut-down, turn remote wall switch to
“OFF.”
2. Open lower control compartment door.
3. Turn the OFF/ON switch to “OFF”. Do not force.
4. Close the main line shut-off valve.
5. Close lower control compartment door.
TO TURN OFF GAS TO APPLIANCE
OPERATING INSTRUCTIONS
1. STOP! Read the safety information above on this page.
2. Turn remote wall switch to “OFF.”
3. Open lower control compartment door.
4. Verify main line shut-off valve is open.
5. Turn the OFF/ON switch to “OFF”. Do not force.
6. Wait five (5) minutes to clear out any gas. Then smell
for gas, including near the floor. If you smell gas, STOP!
Follow “B” in the safety information above (to the left) on
this label. If you don’t smell gas, go to the next step.
7. Turn the OFF/ON switch to “ON”. Do not force.
8. Turn “ON” all electrical power to appliance (remote wall
or appliance switch).
9. Close lower control compartment door.
10.If the appliance will not operate, follow the instructions
"To Turn Off Gas To Appliance" and call your service tech-
nician or gas supplier.
TO SHUT OFF
1. Turn off all electrical power to the appliance (remote wall
switch).
FFO
NI
P
S
I
NO
LORTNOC
GI NTI ER
Honeywell Electronic Gas Control Valve
ON / OFF Switch
Front View