Lennox Hearth II-T C FS Stove User Manual


 
SPECIFICATIONS - Advantage II-T C INS
PAGE 32
Flue Size 3” Standard
Width, Overall front (w/o surround) 25”
Width, Overall back (w/o surround) 24 1/4”
Depth, Overall (w/o surround) 24 3/4”
Height, rear (w/o surround) 19 3/4”
Height, front (w/o surround) 22 3/4”
Floor to Rear
Flue Center 8 1/2”
Fireplace Face to Rear
Flue Outlet Center (3” tee) 17 3/8”
Dimensions into Fireplace
Minimum Height 20 1/8”
Minimum Width @ Front
(extends back 1 ½”) 32”
Minimum Width @ Back 24 5/8”
Minimum Depth 17 3/4”
Facing Back of Unit,
Right Outside Edge of Unit
to Center of Rear Flue Outlet 5”
Floor to Rear
Outside Air Inlet 1 5/8"
Facing Back of Unit,
Right Outside Edge of Unit
to Center of Air Inlet 13”
Floor Protection
Requirements Front: 6”
Standard Features Fastfire Self Igniter
Wall Thermostat (wire
included)
Hopper Capacity 60 lbs.
Burn time 13-46 hours
Fuse, Control Board 5 Amp, 250 VAC *
Fuse, Igniter 6 Amp, 125 volt *
Heat Input (Max.) 11,000-38,000 BTU / hr
Emissions 2.3 gr / hr (varies w/size
and type of fuel) EPA
Certified.
Ship Weight 200 lbs.
Auger Motor 1 RPM; .55 Amps
Room Air Blower 150 CFM; 1.5 Amps
Exhaust Blower 95 CFM: .95 Amps, 3000
rpm
Options Log Set
Gold Trivet
Surround Trim Kit, Gold
FRONT VIEW
SIDE VIEW
Note: Dimensions shown are approximations only (+/-
1/4”)
An approved fireplace hearth or hearth extension is
required 6" to the front of the door. The hearth exten-
sion / floor protector used must be thermal rated (k =
.84, r = 1.19). See Floor Protection, page 5.
Fuel delivery and burn times will vary depending
on size and type of fuel used. Estimated heat in-
put based on fuel value of 8400 BTU per lb.
* Fuses are rated as fast blow.
24 ¾"
Sm. 40 ¾", Med. 44", Lg. 48"
Sm. 28 ½"
Med. 32"
Lg. 36"